Microtomography on the ANATOMIX beamline at Synchrotron SOLEIL

نویسندگان

چکیده

The ANATOMIX beamline at Synchrotron SOLEIL, operational since 2018, is dedicated to hard X-ray full-field tomography techniques. Operating in a range of photon energies from approximately 5 50 keV, it offers both parallel-beam projection microtomography, absorption and phase contrast, nanotomography using zone-plate transmission microscope. With these methods, the covers spatial resolution 20 nm $\mu$m, expressed terms useful pixel size. variable beam size up 40 mm allows users image large objects. Here we describe microtomography instrumentation beamline.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast X-ray reflectivity measurements using an X-ray pixel area detector at the DiffAbs beamline, Synchrotron SOLEIL.

This paper describes a method for rapid measurements of the specular X-ray reflectivity signal using an area detector and a monochromatic, well collimated X-ray beam (divergence below 0.01°), combined with a continuous data acquisition mode during the angular movements of the sample and detector. In addition to the total integrated (and background-corrected) reflectivity signal, this approach y...

متن کامل

Optical design and multi-length-scale scanning spectro-microscopy possibilities at the Nanoscopium beamline of Synchrotron Soleil.

The Nanoscopium 155 m-long beamline of Synchrotron Soleil is dedicated to scanning hard X-ray nanoprobe techniques. Nanoscopium aims to reach ≤100 nm resolution in the 5-20 keV energy range for routine user experiments. The beamline design tackles the tight stability requirements of such a scanning nanoprobe by creating an overfilled secondary source, implementing all horizontally reflecting ma...

متن کامل

Synchrotron radiation computed tomography station at the ESRF biomedical beamline

The different tomography imaging modalities of the ESRF Medical Beamline are described and research applications are presented

متن کامل

Protein crystallography beamline BL2S1 at the Aichi synchrotron

The protein crystallography beamline BL2S1, constructed at one of the 5 T superconducting bending-magnet ports of the Aichi synchrotron, is available to users associated with academic and industrial organizations. The beamline is mainly intended for use in X-ray diffraction measurements of single-crystals of macromolecules such as proteins and nucleic acids. Diffraction measurements for crystal...

متن کامل

SAMBA: The 4–40 keV X-ray absorption spectroscopy beamline at SOLEIL

The SAMBA X-ray Absorption beamline has been operating for users since January 2008. The beamline covers a large energy range from 4 up to 40 keV in two working modes: a “high flux” mode using a sagittally focusing monochromator and a “time-resolved” mode using a dedicated Quick-EXAFS monochromator. Herein a technical description of the main beamline components is given and results concerning e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2022

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2380/1/012122