Microstructured Reactors Designed by Stereolithography and Characterized by Fluorescent Probes
نویسندگان
چکیده
منابع مشابه
Rationally-designed fluorescent lysine riboswitch probes.
Two fluorescent lysine amide analogs, in which the carboxyl end of lysine was covalently attached to dansyl or NBD groups through an ethylene glycol-based linker, were rationally designed and synthesized. Both probes showed high binding affinity to the lysine riboswitch in vitro and their fluorescence intensities decreased by riboswitch binding.
متن کاملMicrostructured reactors for catalytic reactions
This review addresses the catalytic reactions performed in microstructured reactors, which are more and more recognized in recent years as a novel approach for chemistry and chemical process industry. They are particularly suited for highly exothermic and fast reactions allowing temperature control and isothermal operation. A brief evaluation of the advantages for gas-phase, liquid-phase, and g...
متن کاملHydrolysis of Ca2+-sensitive fluorescent probes by perfused rat heart.
Rat hearts were loaded with the fluorescent calcium indicators fura 2, indo 1, rhod 2, or fluo 3 to determine cytosolic calcium levels in the perfused rat heart. With fura 2, however, basal tissue fluorescence increased above anticipated levels, suggesting accumulation of intermediates of fura 2-AM deesterification. To examine this process, we separated the intermediates of the deesterification...
متن کاملHydrolysis of Ca -sensitive fluorescent probes by perfused rat heart
Scaduto, Russell C., Jr., and Lee W. Grotyohann. Hydrolysis of Ca2 -sensitive fluorescent probes by perfused rat heart. Am J Physiol Heart Circ Physiol 285: H2118–H2124, 2003; 10.1152/ajpheart.00881.2001.—Rat hearts were loaded with the fluorescent calcium indicators fura 2, indo 1, rhod 2, or fluo 3 to determine cytosolic calcium levels in the perfused rat heart. With fura 2, however, basal ti...
متن کاملSequencing by Ligation with Double-Labeled Fluorescent Probes
We have synthesized a set of double-labeled fluorescent probes and evaluated the performance of these fluorescent probes in sequencing by ligation (SBL). The results indicated that the ligation efficiency and specificity of double-labeled fluorescent probes was as higher as that of singe-labeled fluorescent probes. Moreover, double-labeled f luorescent p robes y ielded a r emarkable i ncrease i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Photoenergy
سال: 2008
ISSN: 1110-662X,1687-529X
DOI: 10.1155/2008/757510