Microprocessor Based Beam Loss Monitor System for the AGS
نویسندگان
چکیده
منابع مشابه
Secondary Electron Emission Beam Loss Monitor for LHC
Beam Loss Monitoring (BLM) system is a vital part of the active protection of the LHC accelerators’ elements. It should provide the number of particles lost from the primary hadron beam by measuring the radiation field induced by their interaction with matter surrounding the beam pipe. The LHC BLM system will use ionization chambers as standard detectors but in the areas where very high dose ra...
متن کاملA Microprocessor-Based Hybrid Duplex Fault-Tolerant System
Reliability is one of the fundamental considerations in the design of industrial control equipment. The microprocessor-based Hybrid Duplex fault-tolerant System (HDS) proposed in this paper has high reliability to meet this demand although its hardware structure is simple. The hardware configuration of HDS and the fault tolerance of this system are described. The switching control strategies in...
متن کاملA Coaxial Cable Beam Loss Monitor Ion Chamber System for High Power Multi-bunch Beams
Gas filled coaxial cable beam loss monitors are a proven diagnostic in short pulse linacs and transport lines. At the SLAC linear collider (SLC), where the bunch length (σz) is ~ 1 mm, monitor cables with lengths ranging from 100 m to 3 km are used to locate beam losses of 5 x10 8 particles (1.5% of the nominal intensity) with a resolution of +/1 m. The monitor is effective because of the simpl...
متن کاملNew Beam Position Monitor System Design for the APS Injector*
Demands on the APS injector have evolved over the last few years to the point that an upgrade to the existing beam position monitor (BPM) electronics is required. The injector is presently being used as a source for both the low-energy undulator test line (LEUTL) project and the top-up mode of operation. These new requirements and the fact that many new rf receiver components are available at r...
متن کاملBeam Position Monitor System of DAΦNE
The DAΦNE beam position monitor (BPM) system consists of 150 monitors installed all along the machine. Design issues, calibration procedures, experimental results and performance of the system are described. The closed orbit in the main rings is extracted from the BPM signals through narrowband receivers (realized by Bergoz Precision Beam Instrumentation for DAΦNE), then acquired and processed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1979
ISSN: 0018-9499
DOI: 10.1109/tns.1979.4330020