MICROCONTROLLER ATMEGA328P TIMER/COUNTER FOR SINGLE CHANNEL GAMMA SPECTROSCOPY

نویسندگان

چکیده

Soil contamination may occur in the upcoming decommissioning activities of TRIGA2000 Reactor. Measurement contaminant radioactivity, which can be performed using single-channel spectroscopy, is required soil decontamination processes. This research develops a timer/counter system for spectroscopy microcontroller. The performance ATMega328P microcontroller Timer/Counter on Arduino has been tested spectroscopy. Microcontroller's 1 used as counter while 2 timer. Tests include linearity test, comparative and chi-square test. test results show that works well end spectroscopic system.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving Dark Channel Prior for Single Image Dehazing

This paper proposes an improved dark channel prior for removing haze from images. Dark channel prior is an effective method for removing haze. Dark channel is an image in the same size as the hazy image which is obtained by dividing the RGB images into windows and for each window, the minimum of each R, G and B channels are calculated. Then again the minimum of these three values is calculated ...

متن کامل

channel estimation for mimo-ofdm systems

تخمین دقیق مشخصات کانال در سیستم های مخابراتی یک امر مهم محسوب می گردد. این امر به ویژه در کانال های بیسیم با ‏خاصیت فرکانس گزینی و زمان گزینی شدید، چالش بزرگی است. مقالات متعدد پر از روش های مبتکرانه ای برای طراحی و آنالیز ‏الگوریتم های تخمین کانال است که بیشتر آنها از روش های خاصی استفاده می کنند که یا دارای عملکرد خوب با پیچیدگی ‏محاسباتی بالا هستند و یا با عملکرد نه چندان خوب پیچیدگی پایینی...

Instrumentation for Gamma-Ray Spectroscopy

The subject of ttis chapter is the function and operation of the components of a gamma-ray spectroscopy system. In Chapter 3 it was shown that the output pulse amplitude from most gamma-ray detectors is proportional to the energy deposited by the gamma ray. The pulse-height spectrum from such a detector contains a series of full-energy peaks superimposed on a continuous Compton background. Alth...

متن کامل

Transition from analogue-to-digital nuclear electronics for precise gamma radiation spectroscopy: advantages and limitations

In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...

متن کامل

Single Cell Dielectric Spectroscopy in a Micro-channel

We propose the idea of single cell dielectric spectroscopy for future clinical applications such as cell therapy and regenerative medicine. The structure of the microfluidic device is carefully designed to suppress the influence of electrode polarization on the dielectric spectra of single cells. Beads of uniform size distribution is used to determine the detection limit. As feasibility tests f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Jurnal teknologi reaktor nuklir Tri Dasa Mega

سال: 2022

ISSN: ['1411-240X', '2527-9963']

DOI: https://doi.org/10.17146/tdm.2022.24.3.6699