Microbiological Contamination at Workplaces in a Combined Heat and Power (CHP) Station Processing Plant Biomass
نویسندگان
چکیده
منابع مشابه
Microbiological Contamination at Workplaces in a Combined Heat and Power (CHP) Station Processing Plant Biomass
The aim of the study was to evaluate the microbial contamination at a plant biomass processing thermal power station (CHP). We found 2.42 × 10³ CFU/m³ of bacteria and 1.37 × 10⁴ CFU/m³ of fungi in the air; 2.30 × 10⁷ CFU/g of bacteria and 4.46 × 10⁵ CFU/g of fungi in the biomass; and 1.61 × 10² CFU/cm² bacteria and 2.39 × 10¹ CFU/cm² fungi in filtering facepiece respirators (FFRs). Using cultur...
متن کاملAnalysis of the Technological Transition Strategy of Combined Heat and Power (CHP) in Iran
This article identifies the most important barriers that have led to the lack of Combined heat and power (CHP) in Iran in comparison with the national plans. In present study, a model for policy analyzing of combined heat and power technologies on the basis of integrating the two approaches of technological innovation system and multi-level perspective which has been provided. The barriers of C...
متن کاملBiomass for Power Generation and CHP
PROCESSES – Biomass combustion is a carbon-free process because the resulting CO2 was previously captured by the plants being combusted. At present, biomass co-firing in modern coal power plants with efficiencies up to 45% is the most cost-effective biomass use for power generation. Due to feedstock availability issues, dedicated biomass plants for combined heat & power (CHP), are typically of ...
متن کاملRegulatory Compliance and Environmental Benefit Analysis of Combined Heat and Power (CHP) Systems in Taiwan
The energy conservation achieved by utilizing waste heat in the energy and industrial sectors has became more and more important after the energy crisis in the 1970s because it plays a vital role in the potential energy-efficiency improvement. In this regard, cogeneration (combined heat and power, CHP) systems are thus becoming attractive due to the energy, economic, and environmental policies ...
متن کاملEvaluation of Combined Heat and Power (CHP) Systems Using Fuzzy Shannon Entropy and Fuzzy TOPSIS
Combined heat and power (CHP) or cogeneration can play a strategic role in addressing environmental issues and climate change. CHP systems require less fuel than separate heat and power systems in order to produce the same amount of energy saving primary energy, improving the security of the supply. Because less fuel is combusted, greenhouse gas emissions and other air pollutants are reduced. I...