Microanalysis of Dihydroergotoxine by Gas Chromatography/Selected Ion Monitoring (GC/SIM)
نویسندگان
چکیده
منابع مشابه
Determination of corticosterone in rat and mouse plasma by gas chromatography-selected ion monitoring mass spectrometry.
A simple, highly sensitive and specific method based on gas-chromatography-selected ion monitoring (SIM) mass spectrometry has been developed for the quantitation of corticosterone in rat and mouse plasma. After extraction of the plasma with ethyl acetate, the residue was trimethy-silylated with pentafluorobenzyl hydroxylamine-trimethylsilyl (PFBO-TMS). Detection of the derivatives was accompli...
متن کاملDetermination of testosterone in human hair by gas chromatography-selected ion monitoring mass spectrometry.
A method for the determination of testosterone in human hair by gas chromatography-mass spectrometry using d3-testosterone as internal standard is described. Our method consisted of alkaline digestion, fast liquid-liquid extraction, LH-20 chromatography and derivatization with heptafluorobutyric anhydride. Quantification was achieved by selected ion monitoring of m/z 680 (testosterone) and m/z ...
متن کاملThiopental monitoring by gas-chromatography.
A gaschromatographic method is presented for the determination of thiopental (and of its metabolite pentobarbital) in cases of severe head injuries treated by induction of therapeutic barbiturate coma. To 1 ml serum the internal standard and saturated ammonium sulphate solution are added. The mixture is extracted by chloroform and the concentrated organic phase is injected into the gaschromatog...
متن کاملMicroanalysis of fractions of a cubic millimeter of gas.
The method here described permits the sampling, transfer, and deter mination of respiratory gases in approximately 0.35 cmm. samples with errors not greater than ~0.2 volume per cent and in 0.07 c.mm. samples with errors not greater than ~0.5 volume per cent. It will handle up to 100 per cent absorbable gases. The analysis takes 4 to 6 minutes. The method is useful in general when only a minute...
متن کاملSecondary ion microanalysis of fluorine in apatites of biological interest.
A Cameca IMS 300 ion analyzer has been used to measure fluorine concentrations in tooth material. Samples of human and shark teeth were studied. Negative oxygen primary ions produce secondary mass spectra in which positive as well as negative fluorine ion peaks are well re presented. With constant measuring conditions, the reproducibility of the F/Ca ion ratios is satis factory. Fluorine conc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: YAKUGAKU ZASSHI
سال: 1986
ISSN: 0031-6903,1347-5231
DOI: 10.1248/yakushi1947.106.10_900