Micro-Viscometer for Measuring Shear-Varying Blood Viscosity over a Wide-Ranging Shear Rate

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro-Viscometer for Measuring Shear-Varying Blood Viscosity over a Wide-Ranging Shear Rate

In this study, a micro-viscometer is developed for measuring shear-varying blood viscosity over a wide-ranging shear rate. The micro-viscometer consists of 10 microfluidic channel arrays, each of which has a different micro-channel width. The proposed design enables the retrieval of 10 different shear rates from a single flow rate, thereby enabling the measurement of shear-varying blood viscosi...

متن کامل

The criteria for evaluating shear stress measuring range and the lowest measurable shear stress of rotational viscometer.

In the Guidelines for measurement of blood viscosity and erythrocyte deformability by ICSH in 1986, it points out that the viscometer for hemorheology should ideally be able to operate over a wide range of shear conditions, and for a constant shear-rate viscometer a high-shear measurement at 200/second and a low-shear measurement at 1/second (or shear-rates approximating to these values if they...

متن کامل

Shear viscosity of a simple ̄ uid over a wide range of strain rates

ISTVAÂ N BORZSAÂ K*, PETER T. CUMMINGS, and DENIS J. EVANS 1 Institute of Chemistry, Chemical Research Center of the Hungarian Academy of Sciences, P.O. Box 17, Budapest, H-1525, Hungary Departments of Chemical Engineering, Chemistry and Computer Science, University of Tennessee, Knoxville, TN 37996-1508 , USA and Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-61...

متن کامل

Procedure to Evaluate the Shear Rate Profile and the Apparent Viscosity of Non-newtonian Fluids in the Falling Cylinder Viscometer

−− The falling cylinder viscometer (FCV) is a reliable instrument to quantify the viscosity of Newtonian fluids. Nevertheless, when nonNewtonian fluids are tested in this device, difficulties appear to determine the apparent viscosity. Thus, conventional rheometric calculations cannot be applied directly to experimental data provided by the FCV in order to obtain the apparent viscosity function...

متن کامل

Shear rate specific blood viscosity and shear stress of carotid artery duplex ultrasonography in patients with lacunar infarction

BACKGROUND This study describes a new method for determining site-specific vascular shear stress using dynamic measures of shear rate and blood viscosity (BV) in the carotid arteries, and examines characteristics of carotid arterial shear stress among patients with lacunar infarction. METHODS Vascular shear stress measurements were conducted in 37 patients (17 lacunar infarction patients and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2017

ISSN: 1424-8220

DOI: 10.3390/s17061442