Micro-strip metal detector for the beam profile monitoring

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam Test of Silicon Strip Sensors for the ZEUS Micro Vertex Detector

For the HERA upgrade, the ZEUS experiment has designed and installed a high precision Micro Vertex Detector (MVD) using single sided μ-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 μm, with five intermediate strips (20 μm strip pitch). An extensive test program has been carried out at the DESY-II testbeam facility. In this paper we describe the setup dev...

متن کامل

Beam Test of the SDC Double-sided Silicon Strip Detector

A beam test was executed to evaluate the behavior of the first prototype radiation-hard double-sided silicon microstrip sensor for the SDC silicon tracking system. Pions of 4 GeV/c in a test beamline at KEK illuminated three planes of detectors. The signals were amplified, shaped, and discriminated with TEKZ bipolar analog LSI's, and the on-off levels were sampled at 10MHz clock with CMOS digit...

متن کامل

Data Quality Monitoring of the CMS Silicon Strip Tracker Detector

The Physics and Data Quality Monitoring (DQM) framework aims at providing a homogeneous monitoring environment across various applications related to data taking at the CMS experiment. In this contribution, the DQM system for the Silicon Strip Tracker will be introduced. The set of elements to assess the status of detector will be mentioned, along with the way to identify problems and trace the...

متن کامل

A Two-Stage, High Gain Micro-strip Detector

A two stage position-sensitive gas proportional counter has been constructed by tightly coupling a Gas Electron Multiplier (GEM) with a Micro-Groove Detector (MGD). The GEM was used as the first amplifying stage and was optimised to transmit close to 100 % of the primary charge even at very high drift fields (10 kV/cm). Very narrow GEM– MGD separations (0–600 m) were used so that the active vol...

متن کامل

In - Beam Test of Double - Sided Silicon Strip Detector

The response of a double-sided silicon strip detector to a 3 GeV pion beam from the Proton Synchrotron at CERN is presented. Charge matching between the pulseheights from both sides, produced by the same traversing particle, is obtained with a resolution better than 5%. The spatial resolution is measured as a function of the incident angle of the projectile, varying from 15 m at normal incidenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 2007

ISSN: 0168-9002

DOI: 10.1016/j.nima.2007.08.042