Micro grid control strategy of DFIG unit based on improved DC grid connected topology

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decentralized Control Strategy for Optimal Energy Management in Grid-Connected and Islanded DC Microgrids

This paper proposes a decentralized control technique to minimize the total operation cost of a DC microgrid in both grid-connected and islanded modes. In this study, a cost-based droop control scheme based on the hourly bids of all participant distributed generators (DGs) and the hourly energy price of the utility is presented. An economic power sharing technique among various types of DG unit...

متن کامل

Microcontroller Based Novel Dc-to-Ac Grid Connected Inverter Topology

The conventional line commutated ac-to-dc converters/ inverters have square-shaped line current which contains higher-order harmonics. Moreover, it requires a costly and bulky dc inductor or choke. The line current with the high harmonic contents generates EMI and therefore it causes more heating of the core of distribution or power transformers. Alternatively, PWM based inverters using MOSFET/...

متن کامل

Improved Droop Control Strategy for Grid- Connected Inverters

An improved control strategy for grid-connected inverters within microgrids is presented in this paper. The strategy is based on the classical P-ω and Q-V droop method. The improvement in the proposed control strategy is twofold: Firstly, the transient response of the droop controller is improved by replacing the traditional method of measuring average power, which is based on using a first ord...

متن کامل

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

Control Strategy for an Isolated DFIG Based Micro-Grid with Integrated Super-Capacitors

This paper presents a novel control strategy for isolated 4-wires Micro Grid MG based on Wind Turbine WT driven Doubly Fed Induction Generator DFIG with an integrated Super-Capacitors SCs that act as energy storage. The proposed system comprises of variable speed DFIG, DC-link and Grid Side Power Conditioner GSPC. The GSPC is devoted for the MG voltage magnitude and frequency control, balancing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP Conference Series: Materials Science and Engineering

سال: 2017

ISSN: 1757-8981,1757-899X

DOI: 10.1088/1757-899x/199/1/012026