Metrological Evaluation of Robust Relaxation-Oscillator Interface for Remote Resistive Sensors and its Application towards Realizing Few Industrial Measurement Systems

نویسندگان

چکیده

A robust relaxation-oscillator-based conditioning circuit for remotely located resistive sensors is proposed in this article. The uses a simple analog architecture comprising an integrator, Schmitt trigger, inverter, and novel switching logic as its core blocks. provides linear digital indication of the sensor resistance. output independent many non-idealities such bias-current offset voltage Op-amps, connecting lead switch on-resistances, mismatch/drift components power-supply levels. has capability to render all these merits while interfacing with various types configurations. working mechanism analysis are described first performance verified using simulation experimental studies. Later, immunity developed from effect parameters also experimentally verified. Results show that possesses generates low error output. maximum nonlinearity merely 0.07 % when typical single-element-based interfaced circuit. features compared prior art observed be adequate industrial sensors.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A current conveyor-based relaxation oscillator as a versatile electronic interface for capacitive and resistive sensors

Oscillators are widely used as electronic interface for sensors (Filanovsky 1994). This is attributed to their simplicity and immunity to electromagnetic interference (Pallas-Areny and Webster 1991). While harmonic oscillators, widely used with capacitive and inductive sensors, have a very high sensitivity due to their resonant nature, relaxation oscillators are simpler and less sensitive (Pall...

متن کامل

Characterization of an Industrial Sewage Sludge and Its Evaluation for Land Application

Background: Sewage treatment leads to the production of large amount of sludge, containing organic matter and nutrients and considering requirements for recycling could be used as fertilizer. The sludge may also contain various pollutants that pose serious harm to human health and the environment. This study aimed at characterizing the industrial sewage sludge and evaluating its capability as f...

متن کامل

construction and validation of translation metacognitive strategy questionnaire and its application to translation quality

like any other learning activity, translation is a problem solving activity which involves executing parallel cognitive processes. the ability to think about these higher processes, plan, organize, monitor and evaluate the most influential executive cognitive processes is what flavell (1975) called “metacognition” which encompasses raising awareness of mental processes as well as using effectiv...

A smart and accurate interface for resistive sensors

This paper presents a smart and accurate interface for resistive sensors based on the use of a relaxation oscillator. To obtain high accuracy, good long-term stability and a reduction of the effects of interference and parasitic elements, some classical and new measurement techniques have been applied in the novel sensor interface. Moreover, all multiplicative and additive errors, and the commo...

متن کامل

Charge-transfer-based Signal Interface for Resistive Sensors

 Charge transfer has been demonstrated to be a cost-effective method to measure capacitive sensors with low-end microcontrollers. Here we apply charge transfer to measure the output of voltage dividers that include a highvalue resistive sensor hence extending the advantages of this method to a large group of sensors. By using two-point calibration, the maximal deviation obtained, referred to t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE open journal of instrumentation and measurement

سال: 2023

ISSN: ['2768-7236']

DOI: https://doi.org/10.1109/ojim.2023.3287242