Methylene blue immobilized on cellulose acetate with titanium dioxide: an application as sensor for ascorbic acid
نویسندگان
چکیده
منابع مشابه
Methylene Blue Immobilized on Cellulose Acetate with Titanium Dioxide: an Application as Sensor for Ascorbic Acid
Neste trabalho, o corante azul de metileno foi imobilizado na superfície do acetato de celulose modificado com dióxido de titânio produzindo um material híbrido sólido denominado de CA-TiO 2 MB. O experimento produziu uma quantidade de 1,8 mmol g de TiO 2 incorporado no acetato de celulose e uma quantidade de 0,170 0,005 mmol g de azul de metileno adsorvido na superfície do CA-TiO 2 . Um eletro...
متن کاملNile Blue- Chitosan Composite as a new Electrochemical Sensor for Uric Acid on Glassy Carbon Electrode
Nile blue-Chitosan NB-CH as a new type of organic days-organic composite was made using Nile blue and chitosan. The NB-CH composite was made using a 0.005 M solution of Nile blue NB and a 7 solution of chitosan. To do this, a mixture of Nile blue and Chitosan with the ratio of 2:1 was prepared. The electrocatalytic oxidation of uric acid UA has been studied on glassy carbon electrode by NB-CH u...
متن کاملAdsorption and photocatalytic performance of bentonite-titanium dioxide composites for methylene blue and rhodamine B decoloration
Bentonite - TiO2 composites were prepared by impregnation of TiO2 and bentonite, followed by microwave irradiation processes. The composites were characterized using FTIR, SEM, XRD, and nitrogen sorption methods. Anatase phase of TiO2 in all composites are observed through XRD diffraction peaks and surface morphology of the composites. The adsorption and photocatalytic capabilities of the compo...
متن کاملApplication of Genetic Programming as a Powerful Tool for Modeling of Cellulose Acetate Membrane Preparation
متن کامل
COBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID
A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Brazilian Chemical Society
سال: 2008
ISSN: 0103-5053
DOI: 10.1590/s0103-50532008000500020