Method of Calculating Percentage Depth Dose for Diagnostic X-rays
نویسندگان
چکیده
منابع مشابه
Evaluation of depth dose characteristics of superficial X-rays machine using different kVp and applicators diameter
Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being used for radiotherapy treatment. Materials and Methods: Computerized 3-D water phantom of multi-data system was used. The measurements were made...
متن کاملevaluation of depth dose characteristics of superficial x-rays machine using different kvp and applicators diameter
background: radiotherapy treatment planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. this study has been focused to evaluate the depth dose characteristics of superficial x-rays being used for radiotherapy treatment. materials and methods: computerized 3-d water phantom of multi-data system was used. the measurements were made through ...
متن کاملEvaluation of low dose diagnostic X-rays induced effect on the white blood cells count in Guinea pigs
Background: Exposure to ionizing radiation is known to have various effects on hematological parameters of biological sample. This study was aimed at evaluating the effect of ionizing radiation on some hematological parameters in guinea pigs. Materials and Methods: Thirty-six (36) apparently healthy adult guinea pigs of both sexes weighing between 700g – 1200...
متن کاملDiagnostic Utility of Chest X-rays in Neonatal Respiratory Distress: Determining the Sensitivity and Specificity
Background: Chest radiography is one of the most usual diagnostic tools for respiratory distress. Objective: The purpose of this study is to assess the specificity, sensitivity and clinical value of chest radiography of neonates with respiratory distress.Patients and Methods: A descriptive- analytical study was conducted on 102 neonates that were in neonatal intensive care unit of Imam Reza and...
متن کاملEvaluation of depth dose characteristics of superficial X-rays machine using different kVp and applicators diameter
*Corresponding author: Muhammad Ismail, Department of Physics, Bahauddin Zakariya University, Multan, 60800-Pakistan. E-mail: [email protected] Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being use...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 2004
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00000922571