Method for measuring noise‐canceling microphone characteristics
نویسندگان
چکیده
منابع مشابه
A New Method for Measuring the Angle of Hallux Valgus
Objectives. The aim of this study is to introduce a new way and assign its reliability and validity in measuring the angle of hallux valgus. Methods. In this method, we have proceeded to introduce a simple way for measuring the angle of hallux valgus by using ruler and mathematical formulas. For doing this study, we selected 25students and measured their angle of hallux valgus with new way ...
متن کاملA Method for Measuring Energy Consumption in IaaS Cloud
The ability to measure the energy consumed by cloud infrastructure is a crucial step towards the development of energy efficiency policies in the cloud infrastructure. There are hardware-based and software-based methods of measuring energy usage in cloud infrastructure. However, most hardware-based energy measurement methods measure the energy consumed system-wide - including the energy lost in...
متن کاملInvestigation of volume velocity source based on two-microphone method for measuring vibro-acoustic transfer fuctions (bn0439)
Measurement of transfer functions is required for most applications dealing with source-path-contribution techniques often called transfer path analysis. Here the transfer function, typically measured as Frequency Response Function (FRF), takes the role of connecting an input (eg source position) with an output (eg receiver position). In this paper we will further investigate a previously descr...
متن کاملAn event-based method for microphone array speech enhancement
This paper presents the Multi-Channel Multi-Pulse (MCMP) algorithm for the enhancement of speech degraded by reverberations and additive noise. The enhanced speech is synthesized from a sequence of impulses exciting a linear predictive lter. The excitation signal is computed from a nonlinear process which uses impulse clustering of the multi-channel speech data to discriminate portions of the l...
متن کاملA new dual-microphone speech enhancement method for oriented noises
In this paper, we examine a modified Cross-Talk Resistant Adaptive Noise Canceller (CTRANC) structure that contains a delay unit on the primary channel to solve the causality constraint of conventional CTRANC. This Asymmetric CTRANC (ACTRANC) structure allows flexible alignment of noise source with the sensors array when the speech source is fixed in its position. Inserting delay unit on the pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Acoustical Society of America
سال: 1975
ISSN: 0001-4966
DOI: 10.1121/1.2002137