Method for Controlling Frictional Heat inside Superconducting Coils
نویسندگان
چکیده
منابع مشابه
High-Temperature Superconducting RF Coils for 3T MRI
One way to reduce receiving coil noise in MRI scans is using non-resistive high-temperature superconducting (HTS) coils[1]. In this work we built a Bi-2223 tape HTS RF coil and tested its performance. Test results were in agreement with predictions, and a SNR gain of about 2.5 was obtained from the HTS tape coil over a conventional copper surface coil. Introduction Using superconducting coil in...
متن کاملSuperconducting RF Coils for Clinical MR Imaging at Low Field1
Rationale and Objectives. A number of recent reports in the MRI literature have established that substantial signal-tonoise ratio (SNR) gains can be achieved with small samples or low resonance frequencies, through the use of high-quality factor high-temperature superconducting (HTS) RF receive coils. We show the application of HTS coils to the imaging of human subjects with improved SNR compar...
متن کاملTitle Superconducting receiver coils for sodium magnetic resonance imaging
We present the results from sodium magnetic resonance imaging (MRI) experiments using high-temperature superconducting (HTS) receiver coils. Sodium imaging has been shown to have great potential for the assessment of cell integrity but suffers from a substantially lower signal-to-noise ratio (SNR) than that of hydrogen imaging. The use of an HTS receiver coil was found to significantly increase...
متن کاملSimple method for the generation of multiple homogeneous field volumes inside the bore of superconducting magnets
Standard Magnetic Resonance magnets produce a single homogeneous field volume, where the analysis is performed. Nonetheless, several modern applications could benefit from the generation of multiple homogeneous field volumes along the axis and inside the bore of the magnet. In this communication, we propose a straightforward method using a combination of ring structures of permanent magnets in ...
متن کاملEffects of Vertical Misalignment of Superconducting Coils in Cyclotrons
Introduction The vertical misalignment of coil fields with respect to iron fields in cyclotrons can lead to significant beam losses in the course of beam extraction. During commissioning of the Coupled Cyclotron Project at the NSCL unusually high beam losses have been observed on an extraction magnetic element of the K500 cyclotron. The beam loss was first observed on the beam current profiles ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Quarterly Report of RTRI
سال: 2007
ISSN: 0033-9008,1880-1765
DOI: 10.2219/rtriqr.48.115