Metascintillators: New Results for TOF-PET Applications

نویسندگان

چکیده

We report on the progress a first generation of realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved with fast scintillator layers producing bunch prompt photons from energy leakage recoil photoelectric electron. From Geant4 simulation sharing distribution between and 42 LYSO-based BGO-based configurations, detailed study timing performance has been performed selection most promising 12 14 metascintillators. A Monte Carlo was to extrapolate direct measurements metascintillator components, detector time resolution (DTR), sensitivity basis simulated amount scintillator. An analytic algorithm then applied determine an equivalent coincidence (CTR) random association DTR distributions two metapixels in coincidence. This CTR is calculated order obtain same variance reconstructed image as combination 2 metapixels. Preliminary results confirm that these simple still nonoptimized 150 ps 140 can be obtained.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

J-PET analysis framework for the prototype TOF-PET detector

Novel time-of-flight positron emission tomography (TOF-PET) scanner solutions demand, apart from the state-of-the-art detectors, software for fast processing of the gathered data, monitoring of the whole scanner, and reconstruction of the PET image. In this article, we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics ...

متن کامل

Preparation and Quality Control of 68Ga-Citrate for PET Applications

  Objective(s): In nuclear medicine studies, gallium-68 (68Ga) citrate has been recently known as a suitable infection agent in positron emission tomography (PET). In this study, by applying an in-house produced 68Ge/68Ga generator, a simple technique for the synthesis and quality control of 68Ga-citrate was introduced; followed by preliminary animal studies. Methods: 68GaCl3 eluted from the ge...

متن کامل

First results with SiPM tiles for TOF PET based on FBK RGB-HD technology

Fondazione Bruno Kessler, Trento, Italy We present the first results of timing and energy resolution of two newly developed tiles based on FBK RGB-HD SiPMs. The first tile has dimensions of 32×32 mm and is composed of 8×8 SiPMs, with a regular pitch of 4 mm and a cell size of 25×25 μm. Although manufactured with a standard bond wire technology, the tile achieves a fill factor at the tile level ...

متن کامل

Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT

PURPOSE To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. MATERIALS AND METHODS A total of 75 consecutive patients were evaluated in t...

متن کامل

Dynamic comparison of PET imaging performance between state-of-the-art ToF-PET/CT and ToF-PET/MR scanners

GE Healthcare The goal of the present work was to determine the potential for dose reduction in a new clinical ToF-PET/MR scanner. This was achieved by means of long dynamic phantom acquisitions designed to provide a fair comparison of image quality and lesion detectability, as a function of activity, between the new PET/MR system and a state-of-the art PET/CT. A NEMA body phantom was scanned, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE transactions on radiation and plasma medical sciences

سال: 2022

ISSN: ['2469-7303', '2469-7311']