Metallurgical investigation of different causes of center bursting led to wire breakage during production
نویسندگان
چکیده
منابع مشابه
Metallurgical investigation of wire breakage of tyre bead grade
Tyre bead grade wire is used for tyre making application. The wire is used as reinforcement inside the polymer of tyre. The wire is available in different size/section such as 1.6-0.80 mm thin Cu coated wire. During tyre making operation at tyre manufacturer company, wire failed frequently. In this present study, different broken/defective wire samples were collected from wire mill for detailed...
متن کاملinvestigation of gassing behavior, electric and dielectric properties of different insulating fluids.
ترانسفورماتورهای قدرت از اجزای اصلی شبکه تامین انرژی الکتریکی می باشند که عملکرد قابل اطمینان ترانسفورماتورها یکی از فاکتورهای مهم و تعیین کننده در تامین انرژی الکتریکی محسوب می شود. در نتیجه بررسی و مانیتور عملکرد ترانسفورماتورها در شبکه و همچنین عیب یابی این ترانسفورماتورها غیرقابل اجتناب و ضروری می باشد. به طور کلی عایق های مایع در صنعت فشار قوی کاربردهای متفاوتی دارند که مهمترین وظیفه آنها...
15 صفحه اولKirschner Wire Breakage during Removal Requiring Retrieval
Kirschner wires (K-wires) are widely used for fixation of fractures and dislocations in the hand as they are readily available, reliable, and cost-effective. Complication rates of up to 18% have been reported. However, K-wire breakage during removal is rare. We present one such case illustrating a simple technique for retrieval. A 35-year-old male presented with a distal phalanx fracture of his...
متن کاملan investigation of accuracy and complexity across different proficiency levels in written narrative task
abstract this quasi-experimental study was aimed at examining the impact of storyline complexity on the grammatical accuracy and complexity of advanced and intermediate efl learners. a total of 65 advanced and intermediate efl learners were selected from iran language institute (ili). an intact group including 35 intermediate participants and another intact group with 30 advanced participants ...
Breakage of the wire cytology brush during fiberoptic bronchoscopy.
We read with interest the letter by Doctor Sanders (Chest 1983;83:935-56) regarding separation of the wire cytology brush from its attachment to the wire guide during bronchoscopy, and the letters by Doctors Malik and Behera (Chest 1984;85:837-38 and Chest 1985;86:147), Masa-Jimenez et al, and Weissberg (Chest 1985;86:156) regarding breakage of alligator forceps during bronchoscopy. We have exp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Case Studies in Engineering Failure Analysis
سال: 2013
ISSN: 2213-2902
DOI: 10.1016/j.csefa.2013.02.001