Metal Artifact Reduction for Polychromatic X-ray CT Based on a Beam-Hardening Corrector

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Towards Beam Hardening Correction for Polychromatic X-ray Ct

High-attenuation object-induced streaking and shadow artifacts in computerized tomography (CT) are somewhat connected to the misfit of the X-ray projection data to the range space of the Radon transform. This misfit is mainly due to the beam hardening factor of the projection data which is unavoidable for polychromatic sources. The major difficulty in dealing with the beam hardening-induced str...

متن کامل

MR Image Based Approach for Metal Artifact Reduction in X-Ray CT

For decades, computed tomography (CT) images have been widely used to discover valuable anatomical information. Metallic implants such as dental fillings cause severe streaking artifacts which significantly degrade the quality of CT images. In this paper, we propose a new method for metal-artifact reduction using complementary magnetic resonance (MR) images. The method exploits the possibilitie...

متن کامل

A New Method for Metal Artifact Reduction in CT Scan Images

Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...

متن کامل

Metal Artifact Reduction in CT via Ray Profile Correction

In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear assumption made by the analytical CT reconstruction algorithm. The inconsistencies appear in the form of dark and bright bands and streaks in the reconstructed image, collectively called metal artifacts. The standard method for metal artifact reduction (MAR) replaces the inconsisten...

متن کامل

Gaussian diffusion sinogram inpainting for X-ray CT metal artifact reduction

BACKGROUND Metal objects implanted in the bodies of patients usually generate severe streaking artifacts in reconstructed images of X-ray computed tomography, which degrade the image quality and affect the diagnosis of disease. Therefore, it is essential to reduce these artifacts to meet the clinical demands. METHODS In this work, we propose a Gaussian diffusion sinogram inpainting metal arti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Medical Imaging

سال: 2016

ISSN: 0278-0062,1558-254X

DOI: 10.1109/tmi.2015.2478905