Metal Artifact Caused by Magnetic Field Strength and Sequence on T1WI-MRI
نویسندگان
چکیده
منابع مشابه
Magnetic Field Gradient Artifact Reduction on Ecg for Improved Triggering
INTRODUCTION: Due to heart motion, cardiac MRI is made difficult and image acquisitions have to be synchronized with heart activity to suppress cardiac motion artifacts. Electrocardiogram (ECG) is therefore the state-of-the-art signal [1], each MRI acquisition being launched after a fixed delay following a QRS complex detection. The complex MRI environment highly distorts ECG signals, due to th...
متن کاملSEMAC: Slice Encoding for Metal Artifact Correction in MRI.
Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because of severe artifacts, which mainly stem from large metal-induced field inhomogeneities. This work addresses MRI near metallic implants with an innovative imaging technique called "Slice Encoding for Metal Artifact Correction" (SEMAC). The SEMAC technique corrects metal artifacts via robust encoding of each exci...
متن کاملsyngo WARP – Metal Artifact Reduction Techniques in Magnetic Resonance Imaging
■ Through-plane distortion: The local field offset leads to curved and frayed slices instead of the expected flat image plane (Fig. 1). Since both in-plane and through-plane distortions shift image pixels away from their real positions, image geometry appears to be distorted. In both cases, regions with severe field changes will lead to signal voids visible as black spots and signal pileups vis...
متن کاملResponses of alfalfa influenced by magnetic field and rhizobial inoculant
Plants are generally subjected to a combination of different conditions such as magnetic field and soil bacteria in their life. The present investigation tried to compare the effects and interactions of magnetic field and rhizobial inoculant in alfalfa. A pot experiment was performed under a natural condition by a factorial design to ...
متن کاملView-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application
BACKGROUND MRI plays a major role in follow-up of patients with malignant bone tumors. However, after limb salvage surgery, orthopaedic tumor endoprostheses might cause significant metal-induced susceptibility artifacts. PURPOSES To evaluate the benefit of view-angle tilting (VAT) and slice-encoding metal artifact correction (SEMAC) for MRI of large-sized orthopaedic tumor endoprostheses in a...