Abstract A simple analytical method, cheap and biologically friendly, to find Ni (II) in drinking water was developed by dithizone immobilization chloride polyvinyl matrix (PVC) dioctyl phthalate as plasticizers. Nickel is a toxic dangerous metal for humans the environment. The step experimented with making membrane sensor next characterization of UV-Vis spectrophotometry, atomic absorption spectrophotometry (AAS), SEM. ion has caused change color from green brownish red maximum 418 nm optimum response gaining on pH 8,8. proposed size 1 x 2 cm, sample volume ml 0 - 0.06 ppm concentration range. method that had been applied determining after addition standard solution recovery 82.93-109.49 % while measurements obtained 104.11-107.96 %. contained cannot exceed regulation quality PERMENKES RI No: 907/KEMENKES/PER/VII/2010.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

متن کامل

polymeric membrane sensor for potentiometric determination of tin(ii) ions

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

متن کامل

Electrochemical Properties and Antibacterial Activity of Polyvinyl Chloride Supported Silver Molybdate Ion-Exchange Composite Membrane

Polyvinyl chloride supported silver molybdate composite material is used to develop by solution casting method. This membrane was characterized by various instrumental techniques such as Fourier transform infrared (FTIR) spectroscopy, thermogravimetric analysis (TGA) and scanning electron microscopy (SEM) analyses. These characterizations are used to understand the functional groups,thermal sta...

متن کامل

Simple Detection of Mercury Ion Using Dithizone Nanoloaded Membrane

The simple Hg(II)-detection system was studied and developed using dithizone nanofiber loaded membrane. Dithizone is one of the most frequently used chemical substances for Hg(II) ions extraction in water. Hg(II)-dithizone complex substance [Hg(HDith)2] is stable in acidic condition and, presenting with the orange-brown color. To prepare dithizone nanoloaded membrane, dithizone solution (in ace...

متن کامل

Determination of Perchlorate Ion With Tetraphenylarsonium Chloride

A detailed study of precipitation reaction of perchlorate ion with tetraphenylarsonium chloride is reported. Optimum conditions for quantitative precipitation of perchlorate ion were determined. A gravimetric and a spectrophotometric method for perchlorate ion are proposed. The spectrophotometric method is based upon dissolution of ( C.H.),AsClO. in acetonitrile and subsequent measurement of ab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP conference series

سال: 2023

ISSN: ['1757-899X', '1757-8981']

DOI: https://doi.org/10.1088/1755-1315/1228/1/012040