Medium-voltage distribution feeders in open-loop and closed-loop arrangement
نویسندگان
چکیده
منابع مشابه
Medium-voltage distribution feeders in open-loop and closed-loop arrangement
This paper deals with a medium-voltage distribution network. The feeders in the open-loop arrangement are changed to the closed-loop arrangement with the aim to improve reliability of the power supply. The paper focuses on the analysis of transient and steady-state operation in the closed-loop that is established by connecting feeders supplied from two different transformers located in the same...
متن کاملLearning open-loop from closed-loop control
This paper explores an evolution from closed-loop control to open-loop control for a planar manipula-tor. A reinforcement learning strategy is used to learn the open-loop commands from the closed-loop control. The goal is to produce a motion using purely open-loop control strategy, thereby eliminating the need for inter-link communication and on-line control computations. Initially closed loop ...
متن کاملClosed-Loop, Open-Source Electrophysiology
Multiple extracellular microelectrodes (multi-electrode arrays, or MEAs) effectively record rapidly varying neural signals, and can also be used for electrical stimulation. Multi-electrode recording can serve as artificial output (efferents) from a neural system, while complex spatially and temporally targeted stimulation can serve as artificial input (afferents) to the neuronal network. Multi-...
متن کاملOpen-loop and Closed-loop Optimization of Linear Control Systems
A canonical optimal control problem for linear systems with timevarying coefficients is considered in the class of discrete controls. On the basis of linear programming methods, two primal and two dual methods of constructing optimal open-loop controls are proposed. A method of synthesis of optimal feedback control is described. Results are illustrated by a fourth-order problem; estimates of ef...
متن کاملProcess Identification Using Open-loop and Closed-loop Step Responses
This paper is concerned with process identification by curve fitting step responses. Both open-loop and closed-loop identification are studied using simulated data for typical examples as well as experimental data from a laboratory plate heat exchanger. Timedomain curve fitting utilizing efficient local optimization techniques is employed to find the parameters of the process model. Process mod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Renewable Energy and Power Quality Journal
سال: 2012
ISSN: 2172-038X,2172-038X
DOI: 10.24084/repqj10.456