Mechanism and Design Method of Load Transfer into Concrete-Filled Steel Tubular Arch Ribs through Perfobond-Rib-Shear Connectors

نویسندگان

چکیده

In terms of load transfer, the design joints in concrete-filled steel tubular (CFST) arch bridges is more critical than that buildings due to higher likelihood steel–concrete-interface debonding. To improve contact at steel–concrete interface, a novel rib was manufactured by longitudinally welding perfobond-rib-shear connectors inner surface tube and then filling with concrete. this study, extensive numerical analytical investigations on mechanism introducing loads into CFST ribs through were carried out. A deck bridge, namely, Shuangbao Bridge China, selected as typical application location. The parameters, including geometric dimensions connector arrangement perfobond along cross-section longitudinal section rib, evaluated. flow for joint between vertical columns proposed. load-transfer efficiency, scheme optimized replacing weld studs ribs. Significant increases 1.84–4.02 shear resistance found compared welded studs. Additionally, fabrication convenient

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure

Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of ...

متن کامل

Experimental Study on Mechanical Behavior of Shear Connectors of Square Concrete Filled Steel Tube

In order to quantitatively evaluate the shear-bearing capacity of shear connectors of square concrete filled steel tube (CFST), push-out tests on 14 square CFSTs with shear connectors have been carried out. Among the 14 CFSTs, there are 13 specimens with steel plate connectors and one specimen with steel bar connectors. The following factors are investigated to figure out their influences on th...

متن کامل

Temperature Effects and Calculation Method of Closure Temperatures for Concrete-filled Steel Tube Arch Rib of Dumbbell-shape Section

This paper has done continuous on-site experimental researches on temperature field and temperature effects that are under the influence of hydration heat of concrete during the molding process of dumb-bell CFST arch bridge. Analysis on time-history law of temperature field and temperature effects is made. Results reveal that temperature variation of hydration heat of the concrete within the st...

متن کامل

Structural Performance of Steel Pile Caps Strengthened with Perfobond Shear Connectors under Lateral Loading

The conventional strengthening strategy on the connection between the steel pile cap and reinforced concrete footing requires a series of complicated processes such as the distribution of reinforcing bars, their anchorage into concrete, and the usage of shear keys. This study investigates the structural performance of steel pile caps strengthened with newly proposed perfobond shear connectors s...

متن کامل

Seismic Design of Concrete-Filled Circular Steel Bridge Piers

The adequacy of the existing design provisions for concrete-filled steel pipes subjected to axial forces and flexure is reviewed by comparing the strengths predicted by the CAN/CSA-S16.1-M94, AISC LRFD 1994, and the Eurocode 4 1994 codes and standards against experimental data from a number of investigators. New proposed design equations are then developed, in a format compatible with North Ame...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Buildings

سال: 2023

ISSN: ['2075-5309']

DOI: https://doi.org/10.3390/buildings13030807