Mechanical testing of glutaraldehyde cross-linked mitral valves. Part one: In vitro mechanical behaviour

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anticoagulant therapy in Japanese patients with mechanical mitral valves.

There are no guidelines for the optimal therapeutic range of anticoagulant therapy in Japanese patients with mechanical heart valves. A total of 214 patients were followed retrospectively after mitral mechanical valve replacement (mean duration of follow-up, 4.8 years; total duration of follow-up, 1,027 patient-years). The target range of the international normalized ratio (INR) for oral antico...

متن کامل

A mechanical pulse duplicator for testing prosthetic mitral and aortic valves.

The purpose of a prosthetic cardiac valve is to restore the function of a diseased aortic or mitral valve, and its role in haemodynamics is a passive one: the opening and closing of such a valve is strictly regulated by the pressure differences in the cardiac chambers which communicate through this valve. Therefore we consider that a prosthetic valve should be tested under conditions simulating...

متن کامل

Anticoagulation for Mechanical Heart Valves

Although mechanical heart valves (MHV) are more durable than tissue valves, they are more thrombogenic. Consequently, patients with MHV require long-term anticoagulation with vitamin K antagonists, such as warfarin. Although effective, warfarin has well-known limitations, including multiple drug and food interactions, and the challenges of coagulation monitoring and maintaining the internationa...

متن کامل

Mitral mechanical heart valves: in vitro studies of their closure, vortex and microbubble formation with possible medical implications.

OBJECTIVE The goal of the present work was to create the closest possible in vitro fluid dynamic environment in which prosthetic mitral valves in the patients' hearts function, in order to demonstrate whether microbubbles are generated, and if yes, under what conditions and at which stage of the cardiac cycle. Microbubbles were observed in the blood of patients with mitral mechanical heart valv...

متن کامل

Epicardial catheter ablation of ventricular tachycardia in no entry left ventricle: mechanical aortic and mitral valves.

BACKGROUND In patients with mechanical aortic and mitral valves and left ventricular tachycardia, catheter ablation may be prevented by limited access to the left ventricle. METHODS AND RESULTS In our series of 6 patients, 2 patients underwent direct surgical ablation and 4 underwent epicardial catheter ablation via a pericardial window. All patients had abnormal low voltage areas with fracti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

سال: 2020

ISSN: 0954-4119,2041-3033

DOI: 10.1177/0954411920975894