AIM This in vitro study measured the force-deflection behavior of selected initial alignment archwires by conducting three-point bending tests under controlled conditions. The study tested four wire designs: multistranded stainless steel, conventional stainless steel, superelastic nickel-titanium, and thermoactivated nickel-titanium archwires. METHOD The wires (n = 15) were ligated into stain...
متن کاملdetermination of some physical and mechanical properties red bean
چکیده: در این تحقیق، برخی خواص فیزیکی و مکانیکی لوبیا قرمز به-صورت تابعی از محتوی رطوبت بررسی شد. نتایج نشان داد که رطوبت بر خواص فیزیکی لوبیا قرمز شامل طول، عرض، ضخامت، قطر متوسط هندسی، قطر متوسط حسابی، سطح تصویر شده، حجم، چگالی توده، تخلخل، وزن هزار دانه و زاویه ی استقرار استاتیکی در سطح احتمال 1 درصد اثر معنی داری دارد. به طوری که با افزایش رطوبت از 54/7 به 12 درصد بر پایه خشک طول، عرض، ضخام...
15 صفحه اولComparison of Mechanical Properties between Different Orthodontic Stainless Steel Archwires
Introduction: The Damon system recommended the use of revolutionary, hightechnology Damon edgewise 0.019” x 0.025” orthodontic stainless steel archwires (OSSA) for major mechanics and finishing and claimed that this new archwires offer greater efficiency during orthodontic treatment. No study has been carried out to compare this relatively new archwires to other popular OSSA already in the mark...
متن کاملSynergistic effect of wire bending and salivary pH on surface properties and mechanical properties of orthodontic stainless steel archwires
BACKGROUND The aim of this study was to investigate the corrosive behaviour of stainless steel archwires in a more clinically relevant way by bending and exposing to various pH. METHODS One hundred and twenty pieces of rectangular stainless steel wires (0.43 × 0.64 mm) were randomly assigned into four groups. In each group, there were 15 pieces of bent wires and 15 straight ones. Prior to mea...
متن کاملEvaluation of the mechanical properties and surface topography of as-received, immersed and as-retrieved orthodontic archwires
BACKGROUND AND AIMS This experimental study mainly aims at comparing the most important mechanical properties of the new orthodontic archwires, those immersed in fluorinated solution, the as-retrieved ones and the intra-oral used ones. METHODS A total of 270 arch wires were tested, using tensile testing and three-point bending tests. The tested archwires were made of Stainless Steel, Nickel T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Dentistry
سال: 2016
ISSN: 0128-7532,2462-2060
DOI: 10.22452/adum.vol23no1.3