Measuring Subtemporal Subdural Intracranial Pressure using a Catheter-tip Pressure Transducer

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Catheter-tip. Velocity-Pressure Transducer

A catheter-tip velocity transducer with two high-fidelity pressure manometers was used to evaluate the left ventricular (LV) hemodynamic effects of intravenous propranolol (10 mg). Nine patients without clinical evidence of heart failure were studied. Pulsatile ascending aortic blood flow velocity and pressure and LV pressure were measured continuously during drug administration. Beat-to-beat c...

متن کامل

Epidural intracranial pressure measurement in rats using a fiber-optic pressure transducer.

Elevated intracranial pressure (ICP) is a significant problem in several forms of ischemic brain injury including stroke, traumatic brain injury and cardiac arrest. This elevation may result in further neurological injury, in the form of transtentorial herniation(1,2,3,4), midbrain compression, neurological deficit or increased cerebral infarct(2,4). Current therapies are often inadequate to co...

متن کامل

Quantitation of aortic insufficiency using a catheter-tip velocity transducer.

Bidirectional instantaneous aortic root blood flow was measured in 18 patients with aortic insufficiency (AI) using a catheter-tip velocity transducer. The magnitude of AI was quantitated by determining total forward systolic flow from the area of the flow velocity curve above the zero baseline and regurgitant diastolic flow from the curve area below the baseline. Effective forward flow (stroke...

متن کامل

Polyimide/SU-8 catheter-tip MEMS gauge pressure sensor

This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive eleme...

متن کامل

Pressure transducer method for measuring gas production by microorganisms.

A simple method for measuring gas production by microorganisms by using a pressure transducer to sense pressure buildup was developed and tested with members of the coliform group. The test system consisted of a 5.0 lb/in(2) pressure transducer and a pressure equalizer valve attached to the metal cap of a test tube (20 by 150 mm); gas pressure was recorded on a strip-chart recorder. Gas pressur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Neurologia medico-chirurgica

سال: 1986

ISSN: 0470-8105,1349-8029

DOI: 10.2176/nmc.26.147