Measurements on HV-CMOS active sensors after irradiation to HL-LHC fluences
نویسندگان
چکیده
منابع مشابه
Radiation-hard active CMOS pixel sensors for HL-LHC detector upgrades
The luminosity of the Large Hadron Collider (LHC) will be increased during the Long Shutdown of 2022 and 2023 (LS3) in order to increase the sensitivity of its experiments. A completely new inner detector for the ATLAS experiment needs to be developed to withstand the extremely harsh environment of the upgraded, so-called High-Luminosity LHC (HL-LHC). High radiation hardness as well as granular...
متن کاملTrapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 �m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to 3 · 10(15) neq/cm(2). Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the ...
متن کاملModeling of Radiation Damage Effects in Silicon Detectors at High Fluences HL-LHC with Sentaurus TCAD
In this work we propose the application of an enhanced radiation damage model based on the introduction of deep level traps / recombination centers suitable for device level numerical simulation of silicon detectors at very high fluences (e.g. 2.0 × 1016 1 MeV equivalent neutrons/cm2). We present the comparison between simulation results and experimental data for p-type substrate structures in ...
متن کاملTotal Dose Effects on CMOS Active Pixel Sensors
Co irradiations have been carried out on test structures for the development of CMOS Active Pixel Sensors (APS) that can be used in a radiation environment. The basic mechanisms that may cause failure are presented. Ionization induced damage effects such as field leakage currents and dark current increase are discussed in detail. Two different approaches to overcome these problems are considere...
متن کاملMechanical Behaviour of Cyanate Ester/epoxy Blends after Reactor Irradiation to High Neutron Fluences
The mechanical strength of conventional epoxy resins drops dramatically after irradiation to a fast neutron fluence of 1x10 m (E>0.1 MeV). Recent results demonstrated that cyanate ester / epoxy blends were not affected at this fluence level. The aim of this study is to investigate the performance potential of these blends at higher fluence levels without significant degradation of their mechani...