Measurement of Total Serum Protein by Near-Infrared Reflectance Spectroscopy
نویسندگان
چکیده
منابع مشابه
Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares
The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...
متن کاملPotential of Near-Infrared Reflectance Spectroscopy (NIRS) to Predict Nutrient Composition of Bromus tomentellus
Determination of forage quality of available species is one of the fundamentalfactors for the management of rangelands. Near-Infrared Reflectance Spectroscopy (NIRS)was used to analysis the Nitrogen (N), Acid Detergent Fiber (ADF), Dry MatterDigestibility (DMD) and Metabolizable Energy (ME) content of three phenological stages(vegetative, flowering and seeding) of Bromus tomentellus samples in ...
متن کاملEstimating Nitrogen and Acid Detergent Fiber Contents of Grass Species using Near Infrared Reflectance Spectroscopy (NIRS)
Chemical assessments of forage clearly determine the forage quality; however, traditional methods of analysis are somehow time consuming, costly, and technically demanding. Near Infrared Reflectance Spectroscopy (NIRS) has been reported as a method for evaluating chemical composition of agriculture products, food, and forage and has several advantages over chemical analyses such as conducting c...
متن کاملEvaluation of macro elements in forbs species using near infrared reflectance spectroscopy
This article has no abstract.
متن کاملdetermination of protein and moisture in fishmeal by near-infrared reflectance spectroscopy and multivariate regression based on partial least squares
the potential of near infrared reflectance spectroscopy (nirs) as a fast method to predict the crude protein (cp) and moisture (m) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on partial least squares (pls) was evaluated. the coefficient of determination in calibration (r2c) and standard error of calibration (sec) were 0.95 and 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry and Laboratory Medicine
سال: 1988
ISSN: 1434-6621,1437-4331
DOI: 10.1515/cclm.1988.26.4.209