Measurement of the refractive index using a goniometric system

نویسندگان

چکیده

The article proposes a method for measuring the refractive index using goniometric system that does not require prism angle, which simplifies measurement process compared to widely used methods of minimum deviation and autocollimation. This can be measure samples in form triangular prisms visible, ultraviolet infrared ranges. To implement method, was used. obtain reflection refracted beam, fixed mirror used, material calculated from solution equations. results an experimental study made optical glass N-BK7 proposed their comparison with data obtained on State Primary Standard Refractive Index Unit GET 138-2021 are presented. Keywords: goniometer, index, method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of refractive index of PF-5060

For optical studies of boiling heat transfer process, it is essential that the refractive index and its dependence on temperature for the test liquid be known. In this work a simple set-up was built to measure the refractive index of Fluorinert Liquid PF-5060 with temperature compensation and temperature control. The pinhole laser light beam was used for determining the refraction angle. The re...

متن کامل

Needle-based refractive index measurement using low-coherence interferometry.

We present a novel needle-based device for the measurement of refractive index and scattering using low-coherence interferometry. Coupled to the sample arm of an optical coherence tomography system, the device detects the scattering response of, and optical path length through, a sample residing in a fixed-width channel. We report use of the device to make near-infrared measurements of tissues ...

متن کامل

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics and Spectroscopy

سال: 2022

ISSN: ['0030-400X', '1562-6911']

DOI: https://doi.org/10.21883/eos.2022.12.55252.4103-22