Measurement of spatial fluence distribution of neutrons and gamma rays using MAGAT-type gel detector doped with LiCl for BNCT at Kyoto University Reactor
نویسندگان
چکیده
Abstract The spatial distributions of neutrons and gamma rays in the epithermal mode Kyoto University Reactor were measured using a MAGAT-type polymer gel detector doped with LiCl at 6 Li concentrations 0, 10, 100 ppm. Reasonable for thermal obtained 0 100ppm.
منابع مشابه
Progress in Reactor and Accelerator Based BNCT at Kyoto University Research Reactor Institute
متن کامل
exploring motivation and english test preparation strategies of iranian pre-university candidates during and at the end of test preparation period for konkur examination
the current study aimed at investigating the relationship between motivation and test preparation strategies (tpss) used by iranian pre-university students in their preparation period for the university entrance exam (uee). due to the importance of uee in iran, this study also attempted to show its impact on these two important variables. to this end, 100 pre-university students in an iranian p...
Early clinical experience utilizing scintillator with optical fiber (SOF) detector in clinical boron neutron capture therapy: its issues and solutions
BACKGROUND Real-time measurement of thermal neutrons in the tumor region is essential for proper evaluation of the absorbed dose in boron neutron capture therapy (BNCT) treatment. The gold wire activation method has been routinely used to measure the neutron flux distribution in BNCT irradiation, but a real-time measurement using gold wire is not possible. To overcome this issue, the scintillat...
متن کامل- . - , Measurement of Absorbed Dose of Neutrons , and of Mixtures of Neutrons and Gamma Rays
متن کامل
Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods
High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of physics
سال: 2022
ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']
DOI: https://doi.org/10.1088/1742-6596/2167/1/012006