Measurement of Scattered Radiation Dose Around Radiology Unit at Dr. Saiful Anwar Hospital, Malang
نویسندگان
چکیده
منابع مشابه
Clinical picture of diabetic ketoasidosis in Saiful Anwar Hospital Malang, Indonesia, 2005-2009
Results From the 19 patients 58% were girls. 53% were between 5 and 10 years of age. 37% had an equal frequency between 400-600 mg/dl and 600-800 mg/dl of blood glucoses levels. 63% were undernourished. About 53% had moderate DKA. 53% patients had blood bicarbonate concentrations of 5-9,9 mmol/L. Blood osmolarity levels of >295-400 mOsm/l in 84% patients. 53% had blood potassium levels of 3,5-5...
متن کاملPotential effects of xanthone on inflammation status in atherosclerotic rats
1 Department of Cardiology and Vascular Medicine, Ulin General Hospital, Faculty of Medicine, University of Lambung Mangkurat, Banjarmasin, South Kalimantan, Indonesia. 2 Department of Pharmacology, Faculty of Medicine University of Brawijaya, Malang, East Java, Indonesia. 3 Department of Cardiology and Vascular Medicine, Dr. Soetomo General Hospital, Faculty of Medicine, University of Airlangg...
متن کاملOxidants and Antioxidants in Medical Science
1 Department of Cardiology and Vascular Medicine, Ulin General Hospital, Faculty of Medicine, University of Lambung Mangkurat, Banjarmasin, South Kalimantan, Indonesia 2 Department of Pharmacology, Faculty of Medicine, University of Brawijaya, Malang, East Java, Indonesia 3 Department of Cardiology and Vascular Medicine, Dr. Soetomo General Hospital, Faculty of Medicine, University of Airlangga...
متن کاملEvaluation of radiation dose to patients undergoing interventional radiology procedures at Ramathibodi Hospital, Thailand
PURPOSE This study was carried out to assess the radiation dose to patients undergoing interventional radiology procedures at Ramathibodi Hospital, Bangkok, Thailand. METHODS Data were collected from 60 patients under transarterial oily-chemoembolisation (TOCE) and femoral angiography performed with the Toshiba Infinix model VC-i FPD single plane system. Data were also collected from 60 patie...
متن کاملMeasurement of dose in panoramic dental radiology.
The National Radiological Protection Board (NRPB) has recommended the introduction of dose-width product (DWP) for the measurement of patient dose in panoramic dental radiology and has proposed a reference level of 65 mGy mm for adult exposures. This paper describes a method for measuring DWP and dose-area product (DAP) using thermoluminescent dosemeters (TLDs). The technique was used on 16 set...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: KnE Social Sciences
سال: 2018
ISSN: 2518-668X
DOI: 10.18502/kss.v3i11.2796