Measurement of relative oscillator strengths for Ti I - III. Weak transitions from levels a3F3,4 (0.02 eV, 0.05 eV), a5F1-5 (0.81 eV-0.85 eV), a1D2 (0.90 eV), a3P0-3 (1.05 eV-1.07 eV) with solar analysis
نویسندگان
چکیده
منابع مشابه
EV: Replicating Multithreaded Servers
This poster presents EV, a new ExecuteVerify architecture that allows state machine replication to scale to multi-core servers. EV departs from the traditional agree-execute architecture of state machine replication: replicas first concurrently and nondeterministically execute requests; then they verify, agree, and converge on the state and the outputs produced by a correct replica. EV minimize...
متن کاملEv with Hires Stereo
We present the results of a search for small-scale anisotropy in the distribution of arrival directions of cosmic rays above 10 19 eV measured in stereo by the High Resolution Fly's Eye (HiRes) experiment. Performing an autocorrelation scan in energy and angular separation, we find that the strongest correlation signal in the HiRes stereo data set recorded between December 1999 and January 2004...
متن کاملOperational interfaces for EV
This paper provides an overview of the architectural design and use cases underlying advanced smart charging techniques to be implemented in Distribuzione’s EV charging infrastructure, which Italy, is currently deployed under the regulated business model described in [4]. The aim of this development is to demonstrate the operational interfaces between EVSE Operator back-end systems and DSO lega...
متن کاملCellular tropism of human enterovirus D species serotypes EV-94, EV-70, and EV-68 in vitro: implications for pathogenesis.
Enterovirus 94 (EV-94) is an enterovirus serotype described recently which, together with EV-68 and EV-70, forms human enterovirus D species. This study investigates the seroprevalences of these three serotypes and their abilities to infect, replicate, and damage cell types considered to be essential for enterovirus-induced diseases. The cell types studied included human leukocyte cell lines, p...
متن کاملPerformance Characteristics of Beamline 6.3.1 from 200 eV to 2000 eV at the Advanced Light Source
Bend magnet beamline 6.3.1 at the Advanced Light Source operates from 200 eV to 2000 eV, primarily used for x-ray absorption fine structure investigations. The beamline optics consist of a compact, entrance-slitless, HettrickUnderwood type variable-line-spacing plane-grating monochromator and refocusing mirrors to provide a 25 μm x 500 μm spot at the focal point in the reflectometer end station...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Monthly Notices of the Royal Astronomical Society
سال: 1983
ISSN: 0035-8711,1365-2966
DOI: 10.1093/mnras/204.3.883