Measurement of Pressure Distribution on Contact Surface by Transferred Oil Film.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

Purpose. To determine the dynamic pre- and postlens tear film (PLTF and PoLTF) thicknesses by using optical coherence tomography (OCT). Methods. Ultrahigh-resolution OCT was used to image the tear film of 22 subjects before and after contact lens wear. A soft lens with 1 drop of artificial tears on its concave surface was inserted onto one randomly selected eye. OCT images were taken before ins...

متن کامل

Contact pressure distribution in joints formed by V-band clamps

V-band clamps offer an efficient clamping solution in diverse applications including process equipment, exhaust systems and air handling. This paper studies the distribution of interface contact pressure between the V-band and flange when the coupling is established. The determination of the contact area and pressure distribution in a joint is essential information, as it determines the integri...

متن کامل

Effect of Contact Pressure and Frequency on Contact Heat Transfer Between Exhaust Valve and its Seat

The hot gases produced by the internal combustion engines passes through the exhaust valve and causes high temperatures in the exhaust valve and its seat. To avoid damaging the exhaust valve, heat must be transferred from the valve to its seat during the contact they make at the opening and closing cycle. Heat transfer rate from the exhaust valve to its seat is a function of many factors. One o...

متن کامل

Dose Distribution Evaluation and Independent Quality Check of Spherical INTRABEAM™ Applicators via Radiochromic EBT2 Film Measurement

Introduction: The present study was conducted to implement a simple practical independent quality check of depth dose and isotropy of the Intrabeam™ therapeutic X-ray machine using radiochromic EBT2 film. Material and Methods: Theindependent quality check of 1.5, 3.5, and 5-cm spherical Intrabeam™ applicators was accomplished using particular EBT2 film cutting pieces with internal rounded edge...

متن کامل

Presentation of Softness Using Film-Type Electro-Tactile Display and Pressure Distribution Measurement

Electro-tactile display has simple mechanical structure and it can present tactile stimulus. However, electro-tactile display lacks of feedback corresponding to touching motion. In this research, we developed a device that combines an electro-tactile display and pressure distribution sensor. The device not only solves problem of unnatural electrical sensation, but also enables expression of hap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Japan Society for Precision Engineering

سال: 1995

ISSN: 1882-675X,0912-0289

DOI: 10.2493/jjspe.61.372