Measurement of pressure dependent fluorescence yield of air: Calibration factor for UHECR detectors

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors

In a test experiment at the Final Focus Test Beam of the Stanford Linear Accelerator Center, the fluorescence yield of 28.5 GeV electrons in air and nitrogen was measured. The measured photon yields between 300 and 400 nm at 1 atm and 29C are Y (760 Torr) = 4.42 ± 0.73 and Y (760 Torr)2 = 29.2± 4.8 photons per electron per meter. Assuming that the fluorescence yield is proportional to the energ...

متن کامل

A Measurement of the Air Fluorescence Yield

We measured the air uorescence yield as a function of pressure with electrons between 1.4 MeV and 1000 MeV by means of a 90 Sr source and an electron beam. Results indicate that the uorescence yield is proportional to electron energy loss from 1.4 MeV to 1000 MeV. The dE dx relativistic rise in air is detected. We describe the pressure temperature dependency of air uorescence by a formula deriv...

متن کامل

Measurement of air and nitrogen fluorescence light yields induced by electron beam for UHECR experiments

Most of the Ultra High Energy Cosmic Ray (UHECR) experiments and projects (HiRes, AUGER, TA, EUSO, TUS,...) use air fluorescence to detect and measure extensive air showers (EAS). The precise knowledge of the Fluorescence Light Yield (FLY) is of paramount importance for the reconstruction of UHECR. The MACFLY Measurement of Air Cherenkov and Fluorescence Light Yield experiment has been designed...

متن کامل

Absolute Calibration of the Auger Fluorescence Detectors

Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the combined effects of all detector components in a single measurement. The calibrated 2.5 m diameter light source fills the aperture, providing uniform illumination to each pixel. The known flux from the light source and the response of the acqu...

متن کامل

effect of seed priming and irrigation regimes on yield,yield components and quality of safflowers cultivars

این مطالعه در سال 1386-87 در آزمایشگاه و مزرعه پژوهشی دانشگاه صنعتی اصفهان به منظور تعیین مناسب ترین تیمار بذری و ارزیابی اثر پرایمینگ بر روی سه رقم گلرنگ تحت سه رژیم آبیاری انجام گرفت. برخی از مطالعات اثرات سودمند پرایمینگ بذر را بر روی گیاهان مختلف بررسی کرده اند اما در حال حاضر اطلاعات کمی در مورد خصوصیات مربوط به جوانه زنی، مراحل نموی، عملکرد و خصوصیات کمی و کیفی بذور تیمار شده ژنوتیپ های م...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Astroparticle Physics

سال: 2006

ISSN: 0927-6505

DOI: 10.1016/j.astropartphys.2005.12.008