Measurement of Pipe Strain Using an Ultrasonic System
نویسندگان
چکیده
منابع مشابه
Measurement of Thermoplastic Dynamic Modulus using an Ultrasonic Welding System
This paper reports the preliminary results of a newly developed method for measuring dynamic modulus of thermoplastic materials at a given ultrasonic frequency. In the method, a material specimen is squeezed at the tip of the horn of a conventional ultrasonic welding machine. The mechanical impedance of the material specimen under loading is then deduced by processing the input electrical imped...
متن کاملdevelopment of an ultrasonic system and evaluation of effective parameters in ultrasonic measurement of agricultural products
ultrasonic testing (ut), a nondestructive testing (ndt) method, is under development for quality determination of agricultural products, although it has long been used in the food industry. determination and measurement of product quality are important in modern agricultural research. noninvasive/nondestructive quality determination is a novel aspect of the postharvest process in which paramete...
متن کاملNumerical Experiment for Ultrasonic- Measurement-Integrated Simulation of Developed Laminar Pipe Flow Using Axisymmetric Model*
Many studies have been carried out on the relationship between the occurrence and progression of circulatory diseases and hemodynamics. However, it is difficult to obtain accurate and detailed information on blood flow in the living body with existing experimental and numerical methods. The authors have previously proposed the Ultrasonic-Measurement-Integrated (UMI) simulation and shown that th...
متن کاملCalibration Method of an Ultrasonic System for Temperature Measurement
System calibration is fundamental to the overall accuracy of the ultrasonic temperature measurement, and it is basically involved in accurately measuring the path length and the system latency of the ultrasonic system. This paper proposes a method of high accuracy system calibration. By estimating the time delay between the transmitted signal and the received signal at several different tempera...
متن کاملEvaluation of an Ultrasonic Insulin Delivery System in Hyperglycemic Rabbits
Introduction: Sonophoresis has been assessed as a novel approach to create skin permeability and drug delivery using low frequencies of ultrasound waves in the range of 20 kHz to 3 MHz. In this study, a system including seven 40 kHz piezoelectric transducers and an insulin chamber designed by the Medical Physics Research Center has been evaluated on hyperglycemic rabbits. Materials and Methods:...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Current Research in Science, Engineering & Technology
سال: 2018
ISSN: 2581-4311
DOI: 10.30967/ijcrset.1.s1.2018.384-389