Measurement of Neutron Dose Equivalent within and Outside of a LINAC Treatment Vault Using a Neutron Survey Meter

نویسندگان

چکیده

This work concerns neutron doses associated with the use of a Siemens Primus M5497 electron accelerator, which is operated in photon mode at 15 MV. The conditions offer situation within fraction bremsstrahlung emission energies exceed photoneutron threshold. For different field sizes, an investigation has been made dose equivalent values various measurement locations, including: (i) At treatment table, source-surface distance 100 cm; (ii) level floor directly adjacent to table; and (iii) control room patient waiting area. evaluated was found range from 0.0001 8.6 mSv/h, notably greatest value couch (8.6 mSv/h) exceeding on table (5.5 mSv/h). Low ranging unobservable between 0.0002 mSv/h were recorded around measurements floor, study showed be jaws closed. These data, most particularly concerning distribution room, are great importance making steps towards improving safety via provision protective measures.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neutron Contamination Unexpected Dose in Varian LINAC

Introduction: Neutron contamination is very harmful for the patients receiving radiation therapy due to the high relative biological effect of neutrons. Medical linear accelerators head are made up of materials with high atomic numbers, and High-energy photons interaction with heavy materials can produce neutron contamination. In this study, neutron equivalent dose, neutron spe...

متن کامل

a structural survey of the polish posters

تصویرسازی قابلیتهای فراوانی را دارا است

15 صفحه اول

Dose measurement outside of radiotherapy treatment field (Peripheral dose) using thermoluminesent dosimeters

Background: In radiation therapy, peripheral dose or the dose outside the radiotherapy field, is important when anatomical structures with very low dose tolerances are involved. One of these critical organs in pelvic irradiation is testis. The amount of radiation delivered to the testes in radiotherapy must be kept as small as possible, consistent with the limit dose of this organ. The threshol...

متن کامل

Development and Characterization of a Neutron Personal Dose Equivalent Monitor

The authors developed a new neutron-measuring instrument that was designed to measure a neutron personal dose equivalent, Hp(10). This instrument is composed of a conventional moderator-based neutron dose equivalent meter and a neutron shield made of borated polyethylene which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP cal...

متن کامل

Measurement of the Radiation Dose Rates of Patients Receiving Treatment with I-131 Using Telescopic Radiation Survey Meter

Introduction In order to discharge the patients receiving treatment with large radiation doses of 131I for thyroid cancer, it is necessary to measure and evaluate the external dose rates of these patients. The aim of the study was to assess a new method of external dose rate measurement, and to analyze the obtained results as a function of time. Materials and Methods In this study, a telescopic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Quantum beam science

سال: 2021

ISSN: ['2412-382X']

DOI: https://doi.org/10.3390/qubs5040033