Measurement of myocardial blood flow with positron emission tomography: Correction for count spillover and partial volume effects

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Positron emission tomography partial volume correction: estimation and algorithms.

Partial volume effects in positron emission tomography (PET) lead to quantitative under- and over-estimations of the regional concentrations of radioactivity in reconstructed images and corresponding errors in derived functional or parametric images. The limited resolution of PET leads to "tissue-fraction" effects, reflecting underlying tissue heterogeneity, and "spillover" effects between regi...

متن کامل

Measurement of myocardial blood flow with positron emission tomography before and after transmyocardial laser revascularization.

BACKGROUND Transmyocardial laser revascularization (TMLR) has been proposed for treatment of refractory angina. It has been hypothesized that transmural left ventricular channels created by laser improve myocardial blood flow (MBF) in the treated zones. We aimed to assess the effect of TMLR on MBF and coronary vasodilator reserve (CVR). METHODS AND RESULTS We measured MBF by means of PET with...

متن کامل

Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects.

Accuracy in in vivo quantitation of brain function with positron emission tomography (PET) has often been limited by partial volume effects. This limitation becomes prominent in studies of aging and degenerative brain diseases where partial volume effects vary with different degrees of atrophy. The present study describes how the actual gray matter (GM) tracer concentration can be estimated usi...

متن کامل

Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect.

An in vivo technique was developed for measuring the absolute myocardial blood flow with H215O and dynamic positron-emission tomography. This technique was based on a new model involving the concept of the tissue fraction, which was defined as the fraction of the tissue mass in the volume of the region of interest. The myocardium was imaged dynamically by positron-emission tomography, starting ...

متن کامل

Evaluation of partial volume effect correction methods for brain positron emission tomography: Quantification and reproducibility

Quantitative accuracy of positron emission tomography (PET) is decreased by the partial volume effect (PVE). The PVE correction (PVC) methods proposed by Alfano et al., Rousset et al., Müller-Gärtner et al. and Meltzer et al. were evaluated in the present study to obtain guidelines for selecting among them. For accuracy evaluation, the Hoffman brain phantom was scanned with three PETs of differ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Mathematical and Computer Modelling

سال: 1988

ISSN: 0895-7177

DOI: 10.1016/0895-7177(88)90605-x