Measurement of Melt Temperature Distribution along the Cavity Thickness Direction by Using Integrated Thermocouple Sensor

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple ...

متن کامل

Effects of thermocouple electrical insulation on the measurement ofᅡᅠsurface temperature

Analytical, numerical and experimental analyses have been performed to investigate the effects of thermocouple wire electrical insulation on the temperature measurement of a reference surface. Two diameters of type K thermocouple, 80 mm and 200 mm, with different exposed wire lengths (0 mm, 5 mm, 10 mm, 15 mm and 20 mm) were used to measure various surface temperatures (4 C, 8 C, 15 C, 25 C and...

متن کامل

Thermocouple Measurement

In 1822, Thomas Seebeck, an Estonian physician, accidentally joined semicircular pieces of bismuth and copper (Figure 1) while studying thermal effects on galvanic arrangements. A nearby compass indicated a magnetic disturbance. Seebeck experimented repeatedly with different metal combinations at various temperatures, noting relative magnetic fi eld strengths. Curiously, he did not believe that...

متن کامل

Decreasing of thermocouple inhomogeneity impact on temperature measurement error

One of the most effective methods of reducing the impact of error due to acquired thermoelectric inhomogeneity of thermocouples' electrodes is discussed in this article. The method consists in stabilizing the profile of the temperature field along electrodes of the main thermocouple (which measures the temperature of the object). There is also discussed the design of device for profile stabiliz...

متن کامل

Microwave Chemical Sensor Using Substrate-Integrated-Waveguide Cavity

This research proposes a substrate-integrated waveguide (SIW) cavity sensor to detect several chemicals using the microwave frequency range. The frequency response of the presented SIW sensor is switched by filling a very small quantity of chemical inside of the fluidic channel, which also causes a difference in the effective permittivity. The fluidic channel on this structure is either empty o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Seikei-Kakou

سال: 2003

ISSN: 0915-4027,1883-7417

DOI: 10.4325/seikeikakou.15.140