Measurement of low‐energy backscatter factors using GAFCHROMIC film and OSLDs

Some of the lowest voltages used in radiotherapy are termed Grenz and superficial X-rays of ~ 20 and ~ 100 kVp, respectively. Dosimetrically, the surface doses from these beams are calculated with the use of a free in-air air kerma measurement combined with a backscatter factor and the appropriate ratio of mass energy absorption coefficients from the measurement material to water. Alternative t...

متن کامل

Measurement of high energy x-ray beam penumbra with Gafchromic EBT radiochromic film.

High energy x-ray beam penumbra are measured using Gafchromic EBT film. Gafchromic EBT, due to its limited energy dependence and high spatial resolution provide a high level of accuracy for dose assessment in penumbral regions. The spatial resolution of film detector systems is normally limited by the scanning resolution of the densitometer. Penumbral widths (80%/20%) measured at Dmax were foun...

متن کامل

SU-E-I-08: KV XVI Cone Beam-CT Dose Measurement Using Gafchromic XRQA2 Film.

PURPOSE To study the effect of different filters on the dose response curves of the Gafchromic XRQA2 film. To measure the kV XVI cone-beam CT (CBCT) surface dose received during 3D and 4D imaging protocols in three body regions (head and neck, chest and pelvis). METHODS GafChromic XR- QA2 film (International Specialty Products, Wayne, NJ) dose response curves were generated for three irradiat...

متن کامل

Gafchromic EBT3 film dosimetry in electron beams — energy dependence and improved film read‐out

For megavoltage photon radiation, the fundamental dosimetry characteristics of Gafchromic EBT3 film were determined in 60Co gamma ray beam with addition of experimental and Monte Carlo (MC)-simulated energy dependence of the film for 6 MV photon beam and 6 MeV, 9 MeV, 12 MeV, and 16 MeV electron beams in water phantom. For the film read-out, two phase correction of scanner sensitivity was appli...

متن کامل

Dosimetry of gamma chamber blood irradiator using Gafchromic EBT film.

Gafchromic films are increasingly being used for dosimetry in medical and industrial applications of ionizing radiation because of their favorable characteristics such as self developing in nature, easy to handle, dose rate independent response, insensitivity to normal room lights, high resolution and insensitivity to variation in the environment conditions. The dosimetry measurements using Gaf...

متن کامل