Dual-head gamma camera coincidence imaging in pancreatic cancer.

OBJECTIVE To assess the usefulness of dual-head camera imaging with 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG) in the identification of malignant pancreatic lesions. MATERIAL AND METHODS Fifteen (15) patients with pancreatic masses (7 females and 8 males, mean age 52 10 years) have been studied prospectively. After a 12-hour fasting patients received 120 MBq of FDG and were imaged in a dua...

متن کامل

Gaze-Tracking Based on Head-Pose Estimation using Depth Camera

A gaze is an indicator what people focused on. The research purpose is to implement a gaze tracking application so that people know which part of a wide view target is the most interesting. This research uses Kinect Xbox 360 as a tracking device and Visual Studio 2013 as development environment (IDE). The research can be applied in business purpose, such as in advertisement area. This research ...

متن کامل

Assessment of malignancy in pulmonary lesions: FDG dual-head coincidence gamma camera imaging in association with serum tumor marker measurement.

UNLABELLED The purpose of the study was to evaluate the performance of dual-head coincidence gamma camera imaging using FDG in association with serum marker assays in identifying lung carcinoma in patients with abnormal findings on chest radiography. METHODS A prospective evaluation of FDG imaging with coincidence detection emission tomography (CDET) using a dual-head gamma camera combined wi...

متن کامل

Usefulness of dual-head coincidence gamma camera with thick NaI crystals for nuclear oncology: comparison with dedicated PET camera and conventional gamma camera with thin NaI crystals.

AIM A comparative study of the images obtained with a dual-head coincidence gamma camera with thick NaI crystals (19 mm), a dedicated PET camera with BGO crystals and a conventional gamma camera with thin NaI crystals (9.5 mm) was conducted to clarify the clinical feasibility of a dual-head coincidence gamma camera with thick NaI crystals. METHODS FDG images of 27 patients with malignant tumo...

متن کامل

Assessment of 18F-fluorodeoxyglucose dual-head gamma camera in asbestos lung diseases.

The purpose of this study was to evaluate the performance of 18F-fluorodeoxyglucose (18FDG) imaging via coincidence detection emission tomography (CDET) in identifying malignant lesions in subjects exposed to asbestos. A total of 30 patients exposed to asbestos underwent 18FDG-CDET between January 2000 and June 2003. A CDET scan of the thorax and abdomen was performed 60 min after injection of ...