Determination of Pool Boiling Critical Heat Flux Enhancement in Nanofluids

Nanofluids are engineered colloids composed of nano-size particles dispersed in common fluids such as water or refrigerants. Using an electrically controlled wire heater, pool boiling Critical Heat Flux (CHF) of Alumina and Silica water-based nanofluids of concentration less than or equal to 0.1 percent by volume were measured. Silica nanofluids showed CHF enhancement up to 68% and there seems ...

متن کامل

Pool Boiling Heat Transfer Characteristics of Nanofluids by Sung Joong

Nanofluids are engineered colloidal suspensions of nanoparticles in water, and exhibit a very significant enhancement (up to 200%) of the boiling Critical Heat Flux (CHF) at modest nanoparticle concentrations (50.1% by volume). Since CHF is the upper limit of nucleate boiling, such enhancement offers the potential for major performance improvement in many practical applications that use nucleat...

متن کامل

FLOW VISUALIZATION AND STUDY OF CRITICAL HEAT FLUX ENHANCEMENT IN POOL BOILING WITH Al2O3-WATER NANOFLUIDS

Pool boiling heat transfer characteristics of Al2O3 -water nanofluids is studied experimentally using a NiCr test wire of 36 standard wire guage diameter. The experimental work mainly concentrated on (1) change of critical heat flux with different volume concentrations of nanofluid and (2) flow visualization of pool boiling using a fixed concentration of nanofluid at different heat flux values....

متن کامل

Pool boiling of water-Al2O3 and water-Cu nanofluids on horizontal smooth tubes

Experimental investigation of heat transfer during pool boiling of two nanofluids, i.e., water-Al2O3 and water-Cu has been carried out. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. The horizontal smooth copper and stainless steel tubes having 10 mm OD and 0.6 mm wall thickness formed test heater. The experiments have been performed to establish the influence ...

متن کامل

Pool Boiling Heat Transfer in Water/Amines Solutions

In this investigation, nucleate boiling heat transfer coefficients were experimentally measured during pool boiling of mixtures, consisting of water/monoethanolamine and water/diethanolamine on a horizontal heating rod, under atmospheric pressure. The experiment was carried out below 205 kW.m-2 heat flux, over a wide range of concentrations. These experiments include, measurement of pool boilin...