Measurement of Head Scatter Factor for Linear Accelerators using Indigenously Designed Columnar Mini Phantom
نویسندگان
چکیده
منابع مشابه
Calculation the phantom scatter factor for the linear accelerators device
Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. this is important because through simulation, we are fully independent of the spectral scattering factor that we are not able measure in real terms. The effect of the radiation energy, the dimension of the radiation field, the sensitive volume of the ion chamber on t...
متن کاملMeasurement and comparison of head scatter factor for 9MV photon beam using the build-up cap and a columnar mini-phantom
Introduction: The Sc is an important parameter to monitor unit (MU) calculation in radiation therapy procedure. The aim of this study is to measurement and comparison of head scatter factor (Sc) for 9MV photon beam using the build-up cap and a columnar mini-phantom. Materials and Methods: The measurements performed using a calibrated ion chamber (Scanditron...
متن کاملAn Analytical Method to Calculate Phantom Scatter Factor for Photon Beam Accelerators
INTRODUCTION One of the important input factors in the commissioning of the radiotherapy treatment planning systems is the phantom scatter factor (Sp) which requires the same collimator opening for all radiation fields. In this study, we have proposed an analytical method to overcome this issue. METHODS The measurements were performed using Siemens Primus Plus with photon energy 6 MV for fiel...
متن کاملIndigenously designed meconium aspirator.
Meconium stained amniotic fluid (MSAF) complicates delivery in approximately 8% to 25% of live births. Approximately 5% of neonates born through MSAF develop meconium aspiration syndrome (MAS), and approximately 50% of these infants require mechanical ventilation. Meconium aspiration before or during birth can obstruct airways, interfere with gas exchange and cause severe respiratory distress [...
متن کاملIndigenously developed multipurpose acrylic head phantom for verification of IMRT using film and gel dosimetry
The purpose of this study was to validate the newly designed acrylic phantom for routine dosimetric purpose in radiotherapy. The phantom can be used to evaluate and compare the calculated dose and measured dose using film and gel dosimetric methods. In this study, a doughnut-shaped planning target volume (8.54 cm3) and inner organ at risk (0.353 cm3) were delineated for an IMRT test plan using ...