Measurement of GFR with non-radioisotopic radio contrast agents
نویسندگان
چکیده
منابع مشابه
Impact of contrast agents on dose algorıthms of planning systems
Background: Use of contrast agents (CAs) during CT simulation for treatment planing system leads to changes in electron density. In this study we aimed to investigate the effect on calculated dose of various concentrations of CAs on treatment planing systems in different dose calculation algorithms. Materials and Methods: Contrast agent (0.769 mg/ml Iopromid) - water mixtures at con...
متن کاملRadioisotopic assay for measurement of serum folate levels.
A radioisotopic assay is reported that 4 hr and can be run in unlimited quanaccurately measures an almost identical tity. This raclioassay should simplify diserum folate to that measured by Lactoagnosis of folate deficiency and be parbacillus casei and can separate low, ticularly useful in patients receiving borderline, and normal folate levels. This antibiotics and folate antagonists, where as...
متن کامل[Renal transplant blood flow measurement using ultrasonic contrast agents].
We studied the renal transplant blood flow using an ultrasonic contrast agent. The contrast medium was injected intravenously and produced blood flow enhancement for at least 60 seconds. Measurements were made from the recorded Doppler spectra. Fourteen renal transplant recipients were investigated by color Doppler echography. Blood flow in the interlobular artery could be analyzed in all patie...
متن کاملSafety of ultrasound contrast agents: "Primum non nocere"?
Diagnostic ultrasound contrast agents (UCA) are mainly indicated to enhance endocardial border delineation in patients with technically difficult echocardiographic examinations1. They have proven to increase the accuracy and reproducibility of regional and global left ventricular (LV) function assessment at rest2-4 and during stress5,6. UCA are also used for qualitative or quantitative determin...
متن کاملOptimization of Gate’s technique for measurement of GFR during routine renal scan [Persian]
Using Gate’s technique for GFR measurement with Gamma camera, the patient is received 5mCi of Tc-99m-DTPA. By this amount of radioactivity, good quality renal scan is not possible. This study tries to optimize Gate’s technique for GFR measurement during routine renal scan (with 10-15 mCi). Methods and materials: Scanning was performed for 60 seconds from samples of Tc-99m with activities ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Kidney International
سال: 1988
ISSN: 0085-2538
DOI: 10.1038/ki.1988.239