Measurement of Functional Residual Capacity in Rabbits and Children Using an Ultrasonic Flow Meter

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional residual capacity measurements in healthy infants: ultrasonic flow meter versus a mass spectrometer.

Accurate, reproducible and portable bedside monitoring of lung volume could potentially facilitate the early recognition of both under and overinflation of the lungs in ventilated and nonventilated subjects. This study asked whether a prototype portable ultrasonic flow meter provided valid and reliable measurements of functional residual capacity (FRCUS) when compared to those obtained using a ...

متن کامل

Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants.

Small airway disease in infants is characterised by abnormal lung volume and uneven ventilation distribution. An inert tracer gas washin/washout technique using a pulsed ultrasonic flow meter is presented to measure functional residual capacity (FRC) and ventilation distribution in spontaneously breathing and unsedated infants. With a pulsed ultrasound sent through the main stream of the flow m...

متن کامل

Functional residual capacity in healthy preschool children.

The purpose of this study was to evaluate the feasibility of routine functional residual capacity (FRC) measurements in healthy preschool children aged 2.7-6.4 yrs. Furthermore, accuracy and reproducibility were investigated and normal values were collected. A mass-produced closed-circuit helium dilution device (rolling seal) was used. Selection of the 113 healthy children (from the 571 measure...

متن کامل

Evaluation of an Ultrasonic Insulin Delivery System in Hyperglycemic Rabbits

Introduction: Sonophoresis has been assessed as a novel approach to create skin permeability and drug delivery using low frequencies of ultrasound waves in the range of 20 kHz to 3 MHz. In this study, a system including seven 40 kHz piezoelectric transducers and an insulin chamber designed by the Medical Physics Research Center has been evaluated on hyperglycemic rabbits. Materials and Methods:...

متن کامل

norms and ideology in translation of children literature in persian context

اهداف عمده ی این مطالعه دو دسته هستند:1) تعیین هنجار های اجتماعی فرهنگی مورد استفاده در ترجمه ی کتاب کودک برای کودکان ایرانی 2) بررسی مفهوم کودک در ایران و ائدئولوژی این جامعه در رابطه با کودک که مترجم را مجبور به بازسازی کتابهای داستان برای کودکان ایرانی میکند. به این منظور, ابتدا ,مجموعه ای از 30 کتاب داستان و ترجمه های فارسی انها بر اساس مدلlambert and van gorp(2006)مقایسه شد و سپس استراتژیه...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Pediatric Research

سال: 2001

ISSN: 0031-3998,1530-0447

DOI: 10.1203/00006450-200104000-00022