Measurement of Flow Volume in the Presence of Reverse Flow with Ultrasound Speckle Decorrelation
نویسندگان
چکیده
منابع مشابه
the effects of changing roughness on the flow structure in the bends
flow in natural river bends is a complex and turbulent phenomenon which affects the scour and sedimentations and causes an irregular bed topography on the bed. for the reason, the flow hydralics and the parameters which affect the flow to be studied and understand. in this study the effect of bed and wall roughness using the software fluent discussed in a sharp 90-degree flume bend with 40.3cm ...
Simultaneous measurement of water flow velocity with fluorescent and speckle imaging technique
The average velocity of water flow has been simultaneously measured with fluorescent and speckle imaging methods. The measured velocities with two methods are in good agreement with each other and it confirms that the speckle imaging method can be used as a confident method to measure the velocity of water flow in a dry leaf. Also the velocity of water flow through thick and thin xylems of a le...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملcomparison of blood flow velocity changes in posterior cerebral artery measured with transcranial doppler sonography in migraineurs with visual aura and normal persons after photostimulation
چکیده ندارد.
15 صفحه اولProbabilistic Speckle Decorrelation for 3D Ultrasound
Recent developments in freehand 3D ultrasound (US) have shown how image registration and speckle decorrelation methods can be used for 3D reconstruction instead of relying on a tracking device. Estimating elevational separation between untracked US images using speckle decorrelation is error prone due to the uncertainty that plagues the correlation measurements. In this paper, using maximum ent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ultrasound in Medicine & Biology
سال: 2019
ISSN: 0301-5629
DOI: 10.1016/j.ultrasmedbio.2019.07.001