Measurement of falling film thickness around a horizontal tube using laser-induced fluorescence technique
نویسندگان
چکیده
منابع مشابه
Emission reabsorption laser induced fluorescence (ERLIF) film thickness measurement
This paper presents a unique optical technique that utilizes the reabsorption and emission of two fluorescent dyes to accurately measure film thickness while minimizing errors caused by variations in illumination intensity and surface reflectivity. Combinations of dyes are selected that exhibit a high degree of emission reabsorption and each dye concentration is adjusted to create an optically ...
متن کاملDual Emission Laser Induced Fluorescence Technique (delif) for Oil Film Thickness and Temperature Measurement
This paper presents the development and implementation of a Dual Emission Laser Induced Fluorescence (DELIF) technique for the measurement of film thickness and temperature of tribological flows. The technique is based on a ratiometric principle that allows normalization of the fluorescence emission of one dye against the fluorescence emission of a second dye, eliminating undesirable effects of...
متن کاملFast Remaining Thickness Measurement Using a Laser Source Scanning Technique
Fast remaining thickness measurement using Lamb wave is presented for the purpose of maintenance of large structures like oil storage tanks and pipe networks. This study used a laser ultrasonic source to perform a high resolution remote scanning over aluminum plates with grooved and circular defects that were modeled on corrosions in plate-like structures. The antisymmetric A0 and symmetric S0 ...
متن کاملThe thickness of the falling film of liquid around a Taylor bubble
We present the results of laboratory experiments that quantify the physical controls on the thickness of the falling film of liquid around a Taylor bubble, when liquid–gas interfacial tension can be neglected. We find that the dimensionless film thickness l′ (the ratio of the film thickness to the pipe radius) is a function only of the dimensionless parameter Nf = r √ gD3/m, where r is the liqu...
متن کاملAtmospheric ammonia measurement using a VUV/photo-fragmentation laser-induced fluorescence technique.
Vacuum ultraviolet/photofragmentation laser-induced fluorescence has been demonstrated to be a highly specific and sensitive method for the quantitative measurement of atmospheric ammonia (NH(3)). The fluorescence detected in this approach results from the two 193-nm photon photofragmentation step NH(3)?NH(2)? NH(b(1)Sigma(+)) followed by the excitation of the NH(b(1)Sigma(+)) NH(c(1)Pi) transi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2009
ISSN: 1742-6596
DOI: 10.1088/1742-6596/147/1/012039