Measurement of ethylene oxide at a medical sterilization site.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Measurement of ethylene oxide at a medical sterilization site].

Although ethylene oxide gas is widely used as a sterilizing agent for medical instruments because of its disinfection property, the effects of its use in medical settings have not been clarified. In the present study, we measured the ethylene oxide gas concentration (EOGC) within a hospital sterilization unit and in the ambient air near the unit. Before the sterilizer was turned on (about 9:00)...

متن کامل

Ethylene oxide sterilization of medical devices: a review.

Ethylene oxide (EO) is a well-known sterilizing agent. However, only recently has its use significantly emerged, based on its range of applications in the field of new medical device development and sterilization. This paper describes the progress in terms of EO sterilization and concludes that it remains a promising field to explore and develop. The EO action mechanism and toxicity are analyze...

متن کامل

Sterilization by ethylene oxide.

Although sterilization by steam under pressure and by hot air are procedures which are now well understood and efficient when properly conducted, there is an increasing number of objects in medical or surgical use which are too heat labile to be so treated. It is for such items as plastic catheters, disposable plastic syringes, and prostheses that ethylene oxide has been proposed as a convenien...

متن کامل

Portable ethylene oxide sterilization chamber.

A portable ethylene oxide sterilization chamber was designed, constructed, and tested for use in the sterilization of embolectomy catheters. The unit can accommodate catheters up to 40 inches (101.6 cm) in length and can be operated for less than 4 cents per cycle. A constant concentration of 500 mg of ethylene oxide per liter of space and holding periods of 4 and 6 hr at 43 and 22 C, respectiv...

متن کامل

Microbiological Aspects of Ethylene Oxide Sterilization.

Spores of Bacillus subtilis var. niger, dried on nonhygroscopic and hygroscopic surfaces, were enclosed in one of four thicknesses of low-density polyethylene film (2, 4, 6, and 20 mils). The surfaces were then placed in a specially designed thermochemical death rate apparatus and exposed to an ethylene oxide concentration of 600 mg/liter (at 54.4 C) and 50% relative humidity. Survival data, in...