Measurement of electrostatic potential fluctuation using heavy ion beam probe in large helical device
نویسندگان
چکیده
منابع مشابه
Development of 2D Potential Profile Measurements Using the Heavy Ion Beam Probe on the Large Helical Device∗)
Akihiro SHIMIZU1), Takeshi IDO1,2), Masaki NISHIURA3), Hiromi TAKAHASHI1), Hiroe IGAMI1), Yasuo YOSHIMURA1), Shin KUBO1,2), Takashi SHIMOZUMA1), Shinji KATO1), Masayuki YOKOYAMA1,4) and LHD Experiment Group1) 1)National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292, Japan 2)Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa, Nagoya 464-0814, Japan 3)Graduate Sc...
متن کاملProposal of Density and Electrostatic Potential Fluctuation Measurements in the Madison Symmetric Torus with a Heavy Ion Beam Probe
A 200 keV heavy ion beam probe (HIBP) system is being installed on the Madison Symmetric Torus (MST) reversed eld pinch (RFP). Measurements of electron density uctuations and electrostatic potential uctuations in MST are proposed here. For the rst time particle transport induced by electrostatic eld uctuations in the core region of MST can be measured through the simultaneous measurement of ele...
متن کاملAnalysis of heavy ion beam probe potential measurement errors in the Madison Symmetric Torus
The heavy ion beam probe on the Madison Symmetric Torus is capable of measuring the plasma potential at radial locations from about !=r /a=0.3 to 0.75. Radial potential scans from two energy analyzer detectors have been used to assess measurement accuracy since they should produce identical profiles. The effects of analyzer characteristics, system alignment, sample volume locations and shapes, ...
متن کاملFast ion charge exchange spectroscopy measurement using a radially injected neutral beam on the large helical device.
An experimental technique to investigate fast ion confinement based on charge exchange spectroscopy of H(alpha)-light was applied to evaluate the confinement property of perpendicular fast ions in large helical device (LHD). Sensitivities of the H(alpha) spectra to the pitch angles of injected neutral beams (NBs) and these to the angle between the sight line of the measurement and NB injection ...
متن کاملInstallation of Bidirectional Lost Fast-Ion Probe in the Large Helical Device
A bidirectional scintillator-based lost fast-ion probe is installed to measure fast-ion losses induced by energetic-ion-driven magnetohydrodynamic (MHD) instabilities in the Large Helical Device (LHD). It has two set of an aperture assembly so as to measure losses of co-going fast-ions in both clockwise and counterclockwise directions of the toroidal field. Each aperture assembly was designed t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2008
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.2971207