MEASUREMENT OF DEPTH DOSE CURVES IN INHOMOGENEOUS PHANTOM

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose distribution evaluation of various dose calculation algorithms in inhomogeneous media

Background: Dose calculation algorithms play a very important role in predicting the explicit dose distribution. We evaluated the percent depth dose (PDD), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. Materials and Methods: The homogeneous and inhomogeneous virtual slab phantoms used in th...

متن کامل

Estimation of Depth Dose Curves with Sparse Non-equally Spaced Measurements Estimation of Depth Dose Curves with Sparse Non-equally Spaced Measurements

The inverse problem formulation of the depth dose curve estimation is applied to sparse non-equally spaced measurement grid and the subsequent solution as well as the selection of measurement depths are discussed. The performance of the proposed estimation method is evaluated with real 6 MeV and 18 MeV photon data. These studies show that the proposed method allows the estimation of the depth d...

متن کامل

In-phantom depth-dose measurements in mammography utilizing a Compton spectrometer

Mammography, using X-rays, is routinely utilized for screening of patients for prevention of breast cancer. Nevertheless, there is a small but significant risk of radiation induced carcinogenenesis associated with radiation exposure of the breast, being glandular tissue the most sensitive one among the tissues composing breast. Risk estimation in mammography may be determined by the mean absorb...

متن کامل

Evaluation of detectors for acquisition of pristine depth‐dose curves in pencil beam scanning

Acquisition of quasi-monoenergetic ("pristine") depth-dose curves is an essential task in the frame of commissioning and quality assurance of a proton therapy treatment head. For pencil beam scanning delivery modes this is often accomplished by measuring the integral ionization in a plane perpendicular to the axis of an unscanned beam. We focus on the evaluation of three integral detectors: two...

متن کامل

Measurement of Outdoor Background Dose Rate in Ilam Province

Introduction: Background radiation is originated from environmental radioactive sources cosmicandterrestrial.Materials distribution onsurface of the earth and height from sea level are not the same at various points.Absorbed dose caused by them were different at various points.In this research, Background radiation level inoutdoor different areas of Ilam province was measured and effective dose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 1988

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.kj00001360407