Measurement of Coherent Undulator Radiation of Compact Terahertz Radiation Source at Kyoto University
نویسندگان
چکیده
منابع مشابه
Terahertz Coherent Synchrotron Radiation at DAΦNE
We investigate the phenomena related to the emission of coherent synchrotron radiation (CSR) in the Terahertz frequency range at the DAΦNE collider. In particular, we calculate the threshold for the synchrotron radiation (SR) induced single bunch instability, usually referred as microbunching instability (MBI) [1-4]. The MBI can potentially have some effect at very high current in DAΦNE as well...
متن کاملFirst Measurements of the Facet Coherent Terahertz Radiation Source
The Facility for Accelerator science and Experimental Tests (FACET) at SLAC provides a high charge, high peak current, sub-picosecond bunched electron beam that is ideal for 0.1 to 2 THz radiation generation via coherent transition radiation. This paper presents preliminary characterization of the terahertz pulses generated by the FACET electron beam. The measured THz frequency content spans fr...
متن کاملCoherent Radiation Effects in the Lcls Undulator∗
For X-ray Free-Electron Lasers such as LCLS and TESLA FEL, a change in the electron energy while amplifying the FEL radiation can shift the resonance condition out of the bandwidth of the FEL. The largest sources of energy loss is the emission of incoherent undulator radiation. Because the loss per electron depends only on the undulator parameters and the beam energy, which are fixed for a give...
متن کاملInversionless amplification of coherent terahertz radiation
We experimentally demonstrate inversionless amplification of the emission from electronic transitions in a solid state system inside a cavity. A semiconductor-based terahertz (THz) emitter is exposed to a coherent, phasematched THz background field during the emission process leading to an increase in the overall emitted THz power of more than one order of magnitude . The experimental concept a...
متن کاملMeasurement of Coherent Off-axis Undulator Radiation as a Beam Diagnostic
* Corresponding author. Tel.: +301-405-4977. Email [email protected]. Abstract A diagnostic undulator is used to measure relative electron bunch lengths. The radiation produced by the short undulator is observed off-axis so that the beam is not interrupted. Wavelengths radiated which are longer than the bunch length are coherent and may be more intense than the shorter wavelengths by a facto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Magnetics and Electromagnetism
سال: 2017
ISSN: 2631-5068
DOI: 10.35840/2631-5068/6508