Measurement of blood rheology using micromachined channel array.
نویسندگان
چکیده
منابع مشابه
Vibrotactile using micromachined electromagnetic actuators array
One motivating application of this technology is the development of a tactile display interface, where discrete mechanical actuators apply vibratory excitation at discrete locations on the skin. Specifically, this paper describes the development fabrication and characterization of a 4 x 4 micro-actuator array of vibrating pixels for fingertip tactile communication. The vibrting pixels are gener...
متن کاملAcoustic Doppler velocity measurement system using capacitive micromachined ultrasound transducer array technology.
This paper describes the design, fabrication, modeling, and characterization of a small (1 cm(2) transducer chip) acoustic Doppler velocity measurement system using microelectromechanical systems capacitive micromachined ultrasound transducer (cMUT) array technology. The cMUT sensor has a 185 kHz resonant frequency to achieve a 13° beam width for a 1 cm aperture. A model for the cMUT and the ac...
متن کاملPrinciples of blood rheology.
Blood rheology, that embraces the study of the de formation and flow of the blood, is an outbursting science. There are reasons to think that the develop ment of blood rheology (or Hemorheology) will imply deep changes in medical thought concerning the diag nosis, prognosis or therapy of several clinical disor ders. Hemorheology is not a specific field of medicine or of any of the classic speci...
متن کاملA surface micromachined microtactile sensor array
This paper discusses the design and testing of an eight-by-eight tactile capacitive array sensor for detection of sub-millimeter features and objects, where the entire sensor array is smaller than normal human spatial resolution of 1mm. Each square tactel is less than 100μm on a side, with similar spacing between elements. The structural material was doped polysilicon with an air gap dielectric...
متن کاملBlood rheology and aging
The flow properties of blood play significant roles in tissue perfusion by contributing to hydrodynamic resistance in blood vessels. These properties are influenced by pathophysiological processes, thereby increasing the clinical relevance of blood rheology information. There is well-established clinical evidence for impaired blood fluidity in humans of advanced age, including enhanced plasma a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Seibutsu Butsuri
سال: 1997
ISSN: 0582-4052,1347-4219
DOI: 10.2142/biophys.37.254