MEASUREMENT OF BLOOD GLUCOSE LEVEL RATIO FOR MICROVASCULAR FLAP MONITORING
نویسندگان
چکیده
منابع مشابه
Factors affecting blood glucose monitoring: sources of errors in measurement.
Glucose monitoring has become an integral part of diabetes care but has some limitations in accuracy. Accuracy may be limited due to strip manufacturing variances, strip storage, and aging. They may also be due to limitations on the environment such as temperature or altitude or to patient factors such as improper coding, incorrect hand washing, altered hematocrit, or naturally occurring interf...
متن کامل[Self-monitoring of blood glucose].
As the point of care testing(POCT), devices for self-monitoring blood glucose(SMBG) are most common. The problems in SMBG can be found in the popularity of SMBG itself. The reasons for the problems are three. First is the innovation of technology. As each maker has developed devices based on their own intention, device to device difference is too large, so that the standardization is needed. Th...
متن کاملBiochip for minimally invasive blood glucose monitoring
The most common techniques for blood glucose sensing are based on enzymatic glucose oxidation techniques because of being highly sensitive and specific to the glucose. But, the techniques need oxygen environment and the measurement accuracy is affected by the sufficiency of oxygen. In this paper, a new microsystem for minimally invasive monitoring of blood glucose is proposed. The system propos...
متن کاملA new method for the continuous monitoring of blood glucose by measurement of dissolved oxygen.
Glucose concentration may be determined enzymatically by a glucose-oxidase procedure in which the amount of oxygen depletion from a solution saturated with oxygen is observed. The difference between the initial and final oxygen levels as detected by a polarographic oxygen analyzer is a measure of glucose concentration. Blood is sampled continuously by means of a double-lumen catheter inserted i...
متن کاملFlap Salvage Following Postoperative Venous Thrombosis Diagnosed by Blood Glucose Measurement in the Flaps
OBJECTIVE This is the first paper to report the measurement of blood glucose in flaps to detect early flap congestion and flap salvage following immediate flap exploration. METHODS We performed blood glucose measurement in a superficial circumflex iliac artery perforator flap and an anterolateral thigh flap postoperatively using Medisafe-Mini (Terumo, Japan), a regular capillary blood glucose...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Medical and Biomedical Studies
سال: 2019
ISSN: 2589-8698,2589-868X
DOI: 10.32553/ijmbs.v3i8.471